DBI SALA Hot Work NANO-LOK SRL 3101525 Руководство по эксплуатации

APPENDIX A - TWIN SRL FIXED D-RING HARNESS INTERFACE

Older ExoFit Full Body Harnesses with a Fixed D-Ring require a special Twin SRL Harness Interface to mount two
Nano-Lok SRLs on the back of the harness just below the Dorsal D-Ring. The following Twin Nano-Lok SRL models
are available for installation on ExoFit Fixed D-Ring harnesses:
J - 3100128
Twin SRL Fixed D-Ring
Harness Interface
1
Harness Mounting: To mount two Nano-Lok SRLs on an ExoFit Full Body Harness with the Twin SRL Fixed D-Ring
Harness Interface (Figure 15):
1. Loosen the Harness Webbing: Pull out on the Web Straps (A) where they pass through the bottom of the
Back Pad.
2. Open the Harness Interface: With the Twin SRL Interface orientated as illustrated in Figure 15 - Step 2,
push the Locking Sleeve (C) to the right and then turn clockwise to unlock the Gate (D). Swing the Gate (D)
down to open.
3.
the Swivel Eye (F) on the SRL and then rotate the SRL around to the Gate End of the Connector (G). The Gate
can be closed to allow clearance for the Swivel Eye between the Gate and Spine of the Connector.
4.
Web Straps (A). Rotate the Connector behind the Web Straps until the Connector surrounds the Web Straps.
5.
the Connector (E) and position the SRL Swivel Eye in the Nose End of the Connector.
6. Close the Harness Interface: Allow the Gate (D) to swing closed and the Locking Sleeve (C) to rotate back
to locked position. Once the Harness Interface is closed, pull the Web Straps (A) back through the Dorsal
D-Ring to eliminate slack in the webbing and secure the Harness Interface between the Web Straps and Back
Pad.
3101296
Insert the Nose of the Connector (E) behind the
15
Aluminum Rebar Hook
Insert the Nose of the Connector (E) through
Slide the SRL's Swivel Eye (F) over the Nose of
C
2