2.0 Inspection and Unpacking
Inspect shipping container for external damage. All claims for damage (apparent or concealed) or partial loss
of shipment must be made in writing to Dynapar within (5) days from receipt of goods. If damage or loss is
apparent, please notify the shipping agent immediately.
Open shipping container and locate the packing list. The packing list is included to verify that all components,
accessories, and manual were received. Please use the packing list to check off each item as the unit is
unpacked. Inspect for damage. We recommend that the shipping container be retained for future shipping,
storage, or return to factory purposes.
If any equipment was damaged in transit, be sure to file proper claims promptly with the carrier and insurance
company. Please advise us of such filing. In case of parts shortages, advise us immediately. Dynapar cannot
be responsible for any missing parts unless notified within 60 days of shipment.
2.1 Motor Facing and Shaft
To prepare the motor facing and shaft for installation, perform the following steps. See Figure 2.
1. Clean outer rim and surface of motor facing and shaft of paint, grease, dirt, and other debris where
WIND56 unit contacts motor or accessory. Also ensure that mating surfaces have not been damaged and
that unit will fit squarely on motor.
2. Apply a thin layer of corrosion preventative or oil to motor facing and shaft to aid assembly and provide
some corrosion protection.
Ensure there is no paint, burrs, protrusions, or deformations on the
motor facing or shaft. If the enclosure does not fit squarely on the
motor facing, the alignment between the sensor module and the
magnetic pulse wheel may be degraded.