Output operation mode
1. Hysteresis mode [ HYsM
It is able to set certain value for pressure detection
level(ST1, ST2) and hysteresis(HYS1, HYS2).
Pressure
h
h
ON
OUT1 NO
OFF
ON
OUT1 NC
OFF
ON
OUT2 NO
OFF
OUT2 NC
ON
OFF
3. Hysteresis-window comparison output mode [ HY-W
① It is available to set hysteresis mode and window
comparison output mode when both hysteresis
mode(ST1, ST2) and window comparison output
mode(LOW, HIGH) are necessary.
② Detection hysteresis is fixed to min. display range.
Pressure
※ 1
※ 1
ON
OUT1 NO
OFF
ON
OUT1 NC
OFF
ON
OUT2 NO
OFF
OUT2 NC
ON
OFF
5. Forced output control mode [ fOUT
① Used to display pressure with forcibly holding comparing output OFF regardless of setting value.
② In parameter setting, if output operation mode setting 'OUtN' is changed to 'fOUT', forced output control mode is
operated.
③ Output 1, 2 can be ON/OFF manually by pressing
Present pressure value
will be displayed.
Display
ON
Output 1
OFF
ON
Output 2
OFF
HYsM ]
Time
Time
Time
Time
Time
HY-W ]
※ 1: Min. display range
Time
Time
Time
Time
Time
fOUT ]
,
Displays PV and forced
outout mode alternatively
Pressure Sensor
2. Window comparison output mode [ WIN
①It is able to set the range for high(HI-1, HI-2),
low( LO-1, LO-2) limit of pressure detection level when
it is required to detect pressure at a certain range.
② Detection hysteresis is fixed to min. display range.
Pressure
※ 1
※ 1
※ 1
※ 1
ON
OUT1 NO
OFF
ON
OUT1 NC
OFF
ON
OUT2 NO
OFF
ON
OUT2 NC
OFF
4. Automatic sensitivity setting mode [ AUTO
① This function is to set pressure detection level to the
proper position automatically. It is set by applied
pressure from two positions(ST1, ST2).
② Detection hysteresis is fixed to min. display range.
③ The pressure detection level is shown in the following
calculation.
SET = (
Pressure
※ 1
SET=(
+
※ 1
※ 1
ON
OUT1 NO
OFF
ON
OUT1 NC
OFF
ON
OUT2 NO
OFF
ON
OUT2 NC
OFF
key while the forced output control mode is applied.
Present pressure value
will be displayed.
WIN ]
※ 1: Min. display range
Time
Time
Time
Time
Time
AUTO ]
+
)
2
※ 1: Min. display range
)/2
Time
Time
Time
Time
Time
Time
Time
E-13
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
power
supply
(Q)
Stepping
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other