Highnovate RAFA L Инструкция по применению

Просмотреть онлайн или скачать pdf Инструкция по применению для Оборудование для обеспечения безопасности Highnovate RAFA L. Highnovate RAFA L 2 страницы.

MBS Horizontal Pull
MBS Vertical Pull
Wall / Beam Thickness
Weight
RAFA L
Dimensions Folded
Instructions for Use
Certification
RAFA L (Rope Access Fast
Anchor - L)
Tested in Accordance to:
EN795:2012 TYPE B
REGULATION (EU) 2016/425
WARNING!
EXPERT USE
RAFA Parts
ONLY
Made in the Israel using foreign
and domestic materials
These instructions DO NOT inform you of every possible
hazard and every conceivable risk relating to the use of
this equipment.
Connection
The environment where this equipment can be used may
be inherently dangerous. Activities performed within
these environments carry a high risk of injury and death.
Although proper training and experience may reduce this
risk, ultimately the risk cannot be eliminated.
Do not use this equipment unless you fully understand and
assume all risks and responsibilities for all damage / injury
Front Leg
/ death that may result from use of this equipment or the
activities undertaken with it.
This equipment is intended for use by medically fit,
specifically trained and experienced users.
All users of this equipment must obtain and thoroughly
understand the user instructions and refer to them before
each use.
Any time a person is suspended by a rope based system,
a secondary system should be in place in case of a
Installation of the Anchor
component failure. You must always have a backup and
never trust a life to a single tool or component.
The user must have a rescue plan and the means to
1.Start with the folded RAFA
implement it. Inert suspension in a harness can quickly
result in death!
2. Press the Leg Release Buttons (2)
Do not use around electrical hazards, moving machinery, or
near sharp edges or abrasive surfaces.
3. Press the Slider Button in order to extend the legs to fit the structural element.
Do not exceed the working load limit of the equipment.
Verify compatibility with other components of your
system. Incompatible connections can cause detachment,
breakage, etc.
Highnovate is not responsible for any direct, indirect or
accidental consequences or damage resulting from the use
or misuse of this product.
The user must stay up to date! Regularly access the Rock
Exotica website and read the latest advice and user
instructions.
Highnovate
4. Extend the legs and clamp to suitable anchor. Place Slider Beam in contact with the
12 Remez st.
surface of the structural element.
Kiryat Tivon
Israel
(EN) ENGLISH
The RAFA L is a portable and fast anchor device. It was designed
to be used in an urban environment and can be rapidly placed on
a variety of structural elements you can find in a building or on a
roof. It adusts easily to fit different beams, edges, walls etc. The
device can be used as a rope access anchor, or work placement
connection point as part of a PPE system. Afterwards it can be
easily removed or placed In a different spot.
Limitations On Use:
The RAFA L is designed to be part of a PPE system that will
protect the user against falls from height during work activities
when used in conjunction with a full body harness and a device
that limits the load transmitted to the user to 6 KN.
It is impossible to imagine all the ways this equipment can be
misused. It must be used only for the specific purpose it was
designed for; it must not be used for any other. Only the loading
in the "OK" box is allowed. Each user is responsible for making
a risk assessment prior to using this product.
The product was designed to work in a temperature range of -20
to +50 degrees celsius (-4 to 122 degrees fahrenheit).
Lifetime:
Unlimited for metal products, but will often be much less de-
pending on conditions and frequency of use; it could even be a
single use in some cases.
Environmental Factors:
Moisture, ice, salt, sand, snow, chemicals and other factors can
Fig. 5
prevent proper operation or can greatly accelerate wear.
Medical:
It is intended for use by medically fit, specifically trained and
The horizontal pull strength of the RAFA L is
experienced users. Never use this device if you are feeling ti-
dependent upon the length of extension of the Slider
red, drowsy or under the effect of alcohol, drugs or any other
Beam.
substance that may affect your judgement or limits your physical
ability.
Refer to the markings on the top and side of
Compatibility:
the RAFA to verify position of Slider Beam and
Any equipment used with the RAFA L must be certified for use as
associated MBS before use.
Personal Protective Equipment (PPE). An incompatible connec-
tion can cause accidental disconnection, breakage, or affect the
safety function of another piece of equipment. You must verify
the suitability of this equipment for use in your application with
regard to applicable governmental regulations and other stan-
dards on occupational safety.
Re-Sale:
If re-sold outside the original country of destination, CE guidel-
ines require the re-seller of the RAFA L to provide instructions
for use, maintenance, periodic examination and for repair in
the language of the country in which this product is to be used.
Principal Material Aluminum alloy, anodized.
Inspection Before & After Each Use:
In addition to the detailed periodic inspection, the RAFA L must
be inspected before and after each use. Check all parts for
cracks, deformation, corrosion, wear, etc. Verify sliding beam,
leg joints and lever all move and rotate freely. Verify the security
of the Lock Lever when in locked position. Verify that the legs
rotate freely when the Leg Release Button(s) is pushed, and that
the legs lock securely when the button is released. The function
of these parts must not be impaired by foreign matter such as
dirt, ice, corrosion, etc.
If any signs of significant wear appear on the rubber foot pads,
replace them before using the anchor again. A replacement kit
is available from an authorized distributor.
Inspection During Use:
Regularly inspect and monitor your system, confirming the
correct positioning of the RAFA L and tension against the
supporting anchor. Prevent any contact between the RAFA L
anchor and any other objects that can interfere with the ability
to arrest a fall, or move it from its original placement. If during
usage the RAFA L starts to move from its placement, stop using
it immediately. Do not continue until you can establish a suitable
placement.
Detailed Inspection:
In addition to inspection before, during and after each use, a
detailed inspection by a competent inspector must be done at
least every 12 months or more frequently depending on amount
and type of use, government regulations, and environmental
conditions. Check all parts for:
• Sharp edges
• Nicks, gouges, dings, wear, scratches or indentations
deeper than 1mm
• Permanent deformation
SPECS
15 kN, 22 kN
35 x 11 x 8 cm
Tested in accordance to EN795b for two person use
Leg Release
Leg Release
Slider Button
Eye
Button(1)
Slider Beam
Rear Leg
Rear Foot
Front Foot
Locking Lever
5. Press the leg handle completely
down to lock the anchor firmly in a
clamp position.
6. To release the clamp, pull
the end of the sleave outward
and lift up.
Horizontal MBS:
22kN
Position Indicator
22kN Strength Indicator
Horizontal MBS:
15kN
Position Indicator
15kN Strength Indicator
RAFA L
RAFA - L
A.
B.
XXXXXXXXXX
22 kN
C.
Tested in accordance to:
≤ 41 cm
EN795:20012 b
4.5 kg
D.
Two Person Use
(13.7" x 4.3" x 3.1")
E.
WLL: 400kg
Fig. 2
Button(2)
Using the RAFA Anchor
A. Make sure that
the feet fit tightly
and the lever is
locked.
Ok
Connecting to the Anchor
B. Use the connection eye
Fig. 4
to connect a rope or a
ladder to the RAFA using
a standard carabiner or
a sling.
Correct Direction of Load
C. The load should only be applied as indicated "Ok" below. Take precautions
to not pull the anchor in excess of 15 degrees to either side as it may cause
displacement. Do not pull above the achor point.
15° 15°
15° 15°
22kN
15kN
22kN
22kN
22kN
15kN
22kN
36 - 41 cm
F.
G.
MADE IN ISRAEL
H.
A - Model Name
B - Serial Number
C - EN Standard
D - Two Person Use
E - Working Load Limit
F - Read User Manual
G - Manufacturer
H - Country of Origin
No!
Ok
!
No!
• Misalignment of joining parts
• Bent, twisted, distorted, stretched, elongated,
cracked, or broken components
• Unauthorized replacement components
• Legibility of the product markings
• Evidence of:
a. Being dropped
b. Excessive loading
22kN
c. Corrosion
d. Exposure to heat, including weld spatter, arc
strikes, or discoloration of the surface
e. Unauthorized modification or repair
Retire from service immediately if the RAFA:
1. Arrests a fall or is significantly loaded.
2. Does not pass inspection or there is any doubt about its safety.
3. Is misused, altered, damaged, exposed to harmful chemicals,
etc.
Do not return to service until the unit in question has been
inspected and approved for use in writing by a competent
person that is authorized to do so. Contact the manufacturer
if you have any doubts or concerns.
Inspections should be performed by a competent person
whose training meets the applicable standards and/or laws
for the inspection of life safety equipment. An inspection log
including the date, inspectors name, and result of the inspection
should be kept as a permanent record. It is best to issue
new equipment to each user so they know its entire history.
Repairs or modifications to the equipment are only allowed
by the manufacturer or those authorized in writing by the
manufacturer.
Make a copy of these instructions and use one as the permanent
inspection record and keep the other with the equipment. It is
recommended that a similar record is kept for all components
used in a system.
< 36 cm
It is best to issue new gear to each user so they know its entire
history. Periodic detailed inspection shall use the same criteria
as inspection before and after each use. Additionally, periodic
inspection will verify legibility of product markings. User safety
depends upon the durability and correct function of the equip-
ment.
Maintenance & Storage:
Clean if necessary with fresh water, then allow to dry naturally
completely before storing. If there is still dirt in the moving parts,
use air pressure to remove it. Light surface corrosion may be
removed with a wire brush (no power tools). Retire if corrosion
is heavy. Store or transport in a dry place away from extremes of
heat and cold and avoid exposure to chemicals.
With the exception of the rubber feet, repairs or modifications to
equipment are only allowed by the manufacturer or those autho-
rized in writing by the manufacturer.
The RAFA anchor should be placed only on solid parts in a struc-
ture that are strong enough to hold the force that may be applied
during usage. It can be placed on doorways, concrete beams,
window edges and walls that are strong and stable.
Fig. 1
Consult an engineer or a person qualified to assess the strength
of the anchor.
Make sure that the anchor is stable before using. Try to move it to
the sides and to the direction in which it should be loaded. Check
that it is not moving or tilting.
The anchor should normally be above the user's position and
conform to the applicable standard.
The placement should take
into consideration the possibility of a fall
and should minimize the
potential fall distance or hitting an obstacle. You are responsible
to verify the suitability of this equipment and your anchor and
other gear with regard to governmental, and all other other,
applicable standards. The clearance under the user must be
sufficient to prevent him from striking an obstacle in case of a
fall (the length of the connector can influence the height of a fall).
For Fall Arrest:
The user shall be equipped with a means of limiting the maximum
dynamic forces exerted on the user during the
arrest of a fall to a maximum of 6 kN
The full magnitude of force from the load is transmitted through
the RAFA L to the anchors attached to the structure.The maxi-
mum load that can be transmitted is 9kn.
When the RAFA L is used in accordance with EN 795 as a per-
sonal fall protection anchor, the RAFA L shall not be used for
lifting equipment.
To comply with ANSI, follow these requirements:
ANCHORAGE STRENGTH :
The Anchorage strength required depends on the application
type. Following are the requirements of ANSI 359.1 for these
Fig. 3
application types:
Anchorage & anchorage strength :
Anchorage and anchorage strength requirements are dependent
on the full body harness application. In accordance with ANSI
Z3559.1, anchorages selected for fall arrest systems must meet
the anchorage strength requirements defined below.
Anchorage Strength Requirements
Fall Arrest
Non-Certified Anchorage: 5000 lbs. (23 kN)
Certified Anchorage: 2 Times the Maximum Arresting Force for
Certified Anchorage
Restraint
Non-Certified Anchorage: 1,000 (4,5 kN)
Certified Anchorages: 2 times the foreseeable force for certified
anchorages.
Work Positioning
Non-Certified Anchorages: 3,000 lbs (13.3 kN)
Certified Anchorage: 2 times the foreseeable force for certified
anchorage.
Rescue
Non-Certified Anchorage: 3,000 lbs (13.3 kN)
Certified Anchorage: 5 times the foreseeable force for certified
anchorage.
Climbing
The structure which a climbing system is attached must sustain
the loads required by that particular system. See the instructions