6 ELECTRICAL

6.11 Regulations: The electrical installation must be carried out in
6.12 Safety: In the interests of electrical safety a 30 mA residual current
6.13 Before starting work on the electrical supply ensure power supply is
6.14 DO NOT allow the supply cord to contact hot surfaces, including the
6.15 Earthing: This appliance must be earthed via the supply cord, which must be
correctly connected to the earth point located in the terminal box.
6.16 Connections: The pump must be permanently connected to the fixed wiring of
the mains supply using the factory fitted supply cord, via a dedicated double
pole switched fused spur off the ring main.
6.17 Wiring of connection unit:
The wires in the mains lead are coloured in accordance with the following code:
Green and Yellow: Earth
As the colours of the wires in the mains lead of this appliance may not
correspond with the coloured markings identifying the terminals in your
connection unit proceed as follows:
Green and yellow coloured wire must be connected to the terminal in the
connection unit marked with the letter E or by the earth symbol:
green or green and yellow.
Blue coloured wired must be connected to the terminal marked with the letter N
or coloured black.
Brown coloured wire must be connected to the terminal marked with the letter L
or coloured red.
accordance with the current local regulations by a qualified person.
device (R.C.D. not supplied) should be installed in the supply circuit.
This may be part of a consumer unit or a separate unit.
isolated.
motor shell, pump body or pipework. The cord should be safely
routed and secured by cable clips.
WARNING: This appliance must be earthed.
Blue: Neutral
- 11 -
Brown: Live
or coloured
Cont ...