Agtrix 380i Руководство - Страница 8

Просмотреть онлайн или скачать pdf Руководство для Регистраторы данных Agtrix 380i. Agtrix 380i 20 страниц.

P a g e
| 8
INNOVATIVE HARVEST MANAGEMENT AND SUPPLY CHAIN SOLUTIONS

INSTALLING THE LOGGER

PHYSICAL LOCATION

The Logger Should be located in a secure position within the cabin, accessible for
replacement if required, and away from direct sources of heat, including sunlight, or
liquids.
A rubber washers should be fitted between logger and vehicle to minimised vibration
transfer. Avoid mounting too close to other radio equipment, antennas and cables to avoid RF
interference.
Prior to fitting make a note of the unit's serial number and ensure the label is easily
viewable within the vehicle cab for future commissioning and diagnostics.
Inspect for obvious signs of damage prior to fitting. Check integrity of all cables and
connectors.

WIRING OPTIONS - HARVESTER

There are therefore a number of potential wiring configurations
"380i - 2 Inputs Positive Engine (4) and Positive Elevator (5)" (default):
Input 4 - Engine (Positive triggering)
Input 5 - Elevator (Positive triggering)
Optional
Input 1 – Fan (negative triggering)
"380i - 2 Inputs Positive Engine (4) and Negative Elevator (3)"
Input 4 - Engine (Positive triggering)
Input 3 - Elevator (negative triggering)
Optional
Input 1 – Fan (negative triggering)
NOTE: For any other configurations other than the default, please
consult with Agtrix.
Agtrix Pty Ltd
Unit 6, 2 Bonanza Drive, Billinudgel NSW 2483, PO Box 63, New Brighton NSW 2483
Tel +61 (0)2 6680 1309 Email
The logger should be secured within the vehicle where it will
have minimal vibration to avoid contacts becoming
loose. Connecting cables may be positioned and secured to
avoid disengagement (consider use of cable ties for
example) Position the logger to avoid accidental damage by
equipment, tools and other implements.
Web:
www.agtrix.com
ABN 67103038508