5. Run 3 wires, black, white and green (14 AWG), in 1/2"conduit
from service panel to terminal box.
6. Use UL listed wire connectors
and connect black wires
together.
7. Use UL listed wire connectors
and connect white wires
together.
Electrical Shock Hazard
Electrically ground blower.
Connect ground
wire to green and yellow ground wire
in terminal
box.
Failure to do so can result in death or electrical
shock.
8. Connect ground wire to green and yellow ground wire in
terminal box using UL listed wire connectors.
9. Replace terminal box cover.
10. Check all light bulbs to make sure they are secure in their
sockets.
11. Reconnect power.
1. Check lights and blower operation. See "Range Hood Use"
section.
If hood does not operate:
•
Check that the circuit breaker is not tripped or the
household fuse has not blown.
•
Disconnect
power. Check that wiring is correct.
2. For non-vented (recirculating)
installations, install the
charcoal filter. See "Install Filters" section.
3. Place the 2 L-brackets onto the glass hood.
A
A. L-bracket
4. Slide the glass hood on the blower housing.
5. Attach M4 x 35 screws to secure the glass hood.
A
/
A. M4 x 35 screws
6. Install vent cover by placing both vent covers on the hood.
7. Secure lower vent cover to hood with 2 - 2.9 x 6.5 mm
screws, one on either side.
8. Lift upper vent cover to the ceiling.
9. Secure upper vent cover to vent cover bracket with 2 - 2.9 x
6.5 mm screws. Do not completely tighten the lower screws,
but leave a clearance of about V16"(2 mm).
A
A. Vent cover bracket
B. Upper vent cover
C. Lower vent cover
D. 2.9 x 6.5 mm screws
10. Apply 2 rubber strips on the inside of the aesthetic cover.
A
_¸¸
A. Rubber strips
11. Fit over the glass visor. The rubber strips will work to protect
duct covers against any damage when fitting the cover.