RECEIVE J1939
By pressing the "Receive COB" button from the main
window for SW67513 (Fig. 3) the window "Receive CAN
Frame" appears (Fig. 5).
The means of the fields are:
In the field "Data Page" insert the Data Page, in the
J1939 protocol is 0 or 1;
In the field "PGN" insert the PGN of the data you
would to read from Ethernet to J1939 (it is an
identifier);
In the field "Source Address" insert the address of
the device that send the frame;
If the field "Multi Frame" is checked, the Transport
Protocol is enabled for the frame otherwise is
disable;
In the field "StartByte" insert the Start Byte of the
Transport Protocol. Insert a value only if the Multi
Frame is enabled;
In the field "N° Byte" insert the number of bytes that
composed the Transport Protocol. Insert a value only
if the Multi Frame is enabled;
If the field "Cancel Data" is checked, the data in the
frame will be erased after the "TimeOut Data" is
expired;
In the field "Mnemonic" the description for the frame
is defined.
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual J1939 to Ethernet
Document code: MN67213_ENG
Figure 5: "Receive J1939" window
INFO:
www.adfweb.com
Revision 1.002
Page 9 of 16