ROUGH-IN
20007A-PNE-NA installed with 20341T-PNE-CP
478
438
180
230
Finished
floor
A1) INSTALLATION FOR IN-WALL TANK WITH FRAME
The In-wall tank with frame (20007A-PNE-NA) should be used with wall hung toilets.
Note: Minimum cavity (stud pocket) dimensions for installation of the in-wall tank, 555mm wide, 170mm deep.
In-Wall Tank With Frame
1. Remove the front cover or top cover from the tank as shown.
2. Remove the support block from inside of the tank.
3. Remove the plug.
1310920-A02-A
150~185
Air hose
100
Ø90
85~93
UNIT: mm
Note:
Set the final cistern height to achieve the required pan
height.
Nog
Top cover
Supporting
Front
block
cover
-2-
Plug
Front
cover