Kohler KD 500 Руководство по эксплуатации - Страница 35
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Двигатель Kohler KD 500. Kohler KD 500 44 страницы. 51267
64
65
66
67
Workshop Manual KD500 _ cod. ED0053029390 - 1° ed_rev. 00
Counter-shaft float (optional):
Place a calibrated bar on a level with the timing system cover
retention surface and use a thickness gauge to check the
distance between the stop surface and bar (fig. 64). The
measured value must be between:
0,10 ÷ 0,25 mm
Cover on timing system side
Spread liquid seal of the AREXON D 0036 MOTORSIL type on
the retention surface of the timing system cover (fig.65).
Place the cover on the casing.
Insert the cover fixing screws, making sure that the five shorter
ones (40 mm) are mounted in the top part of the cover. Tighten
to the following torque value:
2,7 ÷ 2,8 kgm (26,5 ÷ 27,5 Nm)
Oil retention rings
1. Immerse the retention ring in oil for about 10 minutes.
2. Clean the housing and insert the ring with a plug, exercising
an even pressure all over the surface (fig.66).
Flywheel
Block the flywheel (fig. 67) and torque the nut to value:
18 ÷ 20 kgm (176,5 ÷ 196,1 Nm)
13
Engine assembly
- 35 -
- 35 -