A.J.Antunes roundup ES-600 Руководство пользователя - Страница 11
Просмотреть онлайн или скачать pdf Руководство пользователя для Яйцеварка A.J.Antunes roundup ES-600. A.J.Antunes roundup ES-600 16 страниц. Egg station
To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip-
ment should be performed by qualified service personnel. The unit should be unplugged when servicing.
Problem
Unit fails to operate and
control panel lights fail
to signal on.
Unit fails to heat.
Eggs do not cook prop-
erly.
Eggs sticking to Platen.
Eggs sticking to Egg
Rings.
Not signaling on "Bacon"
or "Ready".
If the troubleshooting steps listed do not solve your problem, contact an A.J. Antunes Authorized Service
Agency for further assistance.
P/N 1010883 08/05 Rev. A
TROUBLESHOOTING
Possible Cause
No power/low power.
Inoperable electrical outlet.
Inoperable rocker (power On/Off)
switch.
Inoperable power cord.
Loose Connections.
Loose connections.
Inoperable Platen.
Low voltage.
Inoperable Hi-Limit Thermostat.
Inoperable Thermocouple.
Inoperable Solid State Relay.
Using refrigerated eggs and time
selector switch set for 2' 00".
Time selector switch is set for 2' 30"
(eggs overcooked).
Incorrect amount of water added to
trough in cover.
Platen temperature too low or too
high.
Loose connections.
Unit/table is not level
Dirty Platen.
Insufficient butter being used.
Insufficient butter being used.
Dirty Egg Rings.
Inoperable Egg Ring.
Inoperable indicator light or audio
signal.
Inoperable control board.
Loose connection.
Bacon Timer is disabled.
EGG STATION (ES-600 & ES-1200)
WARNING
Make sure the Rocker Switch (power On/Off)
is ON and the power cord is locked into place.
Check the main circuit breakers.
Plug the power cord into a different outlet of
same amperage rating.
Contact your maintenance person or an
Authorized Service Agency.
Contact your maintenance person or an
Authorized Service Agency.
Set time selector switch to 2' 30" when using
refrigerated eggs.
Set time selector switch to 2' 00" when using
room temperature eggs.
Fill trough in cover with water before starting time
cycle.
Check the Platen temperature according to the
Maintenance section of this manual.
Contact your Authorized Service Agency.
Level the table and unit as necessary.
Clean Platen.
Refer to the Operating section of this manual.
Refer to the Operating section of this manual.
Do not use an abrasive scrubbing pad to clean
Egg Rings.
Replace Egg Ring.
Contact your maintenance person or an
Authorized Service Agency.
Enable Bacon Timer according to the Operation
section of this manual.
11
Corrective Action