Aqua Link UV-C TECH 75W Руководство - Страница 6

Просмотреть онлайн или скачать pdf Руководство для Сантехническая продукция Aqua Link UV-C TECH 75W. Aqua Link UV-C TECH 75W 8 страниц.

UV-C TECH

OPERATION

EN
In the UV-C Tech, a UV-C radiation with a wavelength of 253.7 nm is generated by the special UV-C
lamp, ensuring a lethal effect on bacteria, viruses and moulds (including Legionella bacteria and
Cryptosporidium). The UV-C Tech will ensure that your pool water is clean, fresh and clear in an
efficient and environmentally-friendly manner. The water is led through the UV-C device via a pump.
The UV-C radiation neutralises bacteria, viruses and other microorganisms and stops them from
multiplying. The UV-C Tech has a built-in electronic ballast. This ballast ensures optimum
performance of the lamp. In addition, the stainless steel interior of the reactor ensures the reflection
of the UV-C rays, thereby increasing the efficiency up to 35%. Thanks to the UV-C Tech, your
swimming pool water will be disinfected efficiently and safely, and the quality of your water will
remain excellent.
* The UV-C Tech 130 watt amalgam lamp is not affected by temperature fluctuations in the water
and generates a constant, powerful radiation.
INSTALLATION OF THE EARTH (DRAWING 1)
1. Pull the cable (2) through the strain relief (4) before fitting the synthetic strain relief (4) onto the earth
bolt (1). Position the strain relief (4) at approximately 10 cm from the eye (2) of the earth cable.
2. Place the eye (2) of the cable onto the earth bolt that is fitted to the housing.
3. Then place a toothed lock washer (3).
4. Fit the strain relief (4), creating a loop of Ø5 cm.
5. Finally place the second toothed lock washer (5) and the lock nut (6) onto the earth bolt.
6. Once the parts have been placed onto the earth bolt in the correct sequence, they can be
tightened with a spanner or a ring spanner number 8.
INSTALLATION OF THE UV-C DEVICE (DRAWING 2)
Determine where the device will be installed. The UV-C Tech must never be installed behind the Ph
regulator or the salt electrolysis system in your swimming pool installation. The ideal location to
install your device is immediately behind the filter. The installation must always take place outside of
the pool. Ensure that there is always water flowing through the unit when the lamp is on. Never
install the unit in an area exposed to full sunlight. The installation must always take place in a dry
and well-ventilated area. The device must be fitted in the vertical position, and a space of 30 cm
must be available underneath to carry out maintenance. An area of approx. 1.5 m must be available
at the top in order to be able to replace the lamp (K) smoothly without having to dismantle the
complete device.
1. Unscrew the screw ring (N) from the housing (U). Remove the UV-C lamp (K) from the supplied
case (see packaging) and carefully slide the lamp into the quartz glass (M). Carefully connect the
white lamp holder (L) to the UV-C lamp (K) and then screw the screw ring (N) hand-tight onto
the housing (U).
| UV-C TECH
6
Please read through these instructions for use
carefully before installing this device.