Power Supplies
Maximum inrush current Under typical line conditions and over the entire system ambient operating
Available Hard Drive Power (Per Slot)
Supported hard drive power
consumption (continuous)
Physical
Height
Width
Depth
Weight (maximum configuration)
Weight without drives
Environmental
For additional information about environmental measurements for specific storage system
configurations, see dell.com/environmental_datasheets.
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
SCv2000/SCv2020 Technical Specifications
range, the inrush current may reach 45 A per power supply for 40 ms or less
Up to 1.2 A at +5 V
Up to 0.5 A at +12 V
8.79 cm (3.46 in.)
48.2 cm (18.98 in.)
SCv2000: 54.68 cm (21.53 in.)
SCv2020: 54.68 cm (21.53 in.)
SCv2000: 29 kg (64 lb)
SCv2020: 24 kg (53 lb)
SCv2000: 21 kg (46 lb)
SCv2020: 19 kg (41 lb)
5° to 57°C (41° to 135°F) with a maximum temperature gradation of 10°C per
hour
52°C (126°F) maximum 2,000 to 3,048 m (6,562 to 10,000 ft)
47°C (117°F) maximum 3,048 to 4,000 m (10,000 to 13,123 ft)
–40° to 65°C (–40° to 149°F) at a maximum altitude of 12,000 m (39,370 ft)
10% to 80% (noncondensing) with 29°C (84.2°F) maximum dew point
5% to 95% (noncondensing) with 33°C (91°F) maximum dew point
0.21 G at 5–500 Hz for 15 min
1.04 G at 2–200 Hz for 15 min
Half-sine shock 5 G +/- 5% with a pulse duration of 10 ms +/- 10% (in
operational orientations only)