Dell Networking N2024 Руководство по установке - Страница 48
Просмотреть онлайн или скачать pdf Руководство по установке для Переключатель Dell Networking N2024. Dell Networking N2024 49 страниц.
Также для Dell Networking N2024: Обновление микропрограммы (21 страниц)
Example of Provisioning a Port Extender
Dell(conf)# feature extended-bridge
Dell(conf)# pe provision 2
Dell(conf-pe-2)# stack-unit 0 type n3048p
Dell(conf-pe-2)# cascade interface tengigabitethernet 0/1–2
Dell(conf-pe-2)# exit
Dell(conf)# interface range tengigabitethernet 0/1-2
Dell(conf-if-te-0/1–2)# no shutdown
Dell(conf-if)# end
Dell# show pe brief
--
Port Extenders Information
----------------------------------------------------------
PE-id
Status
Stack-size
----------------------------------------------------------
2
online
NOTE:
If the status of a port extender is error, communication with an attached C9010 was unsuccessful, possibly due to a
mismatch in software version (SVM) or another communication error. Wait five minutes for an auto-upgrade of the port
extender to complete. If the status does not change to online, contact Dell Networking Support for assistance.
Dell# show pe 2
Codes:
A - Active, I - Inactive
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown Error
PE-ID assigned: 2
Status: online
System Mac: 34:17:eb:00:bb:11
PE Up Time: 00:01:48
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 0/1(A),Te 0/2(A)
Dynamically Discovered Cascade Ports: None
Cascade LAG: Po 258(Up)
------------------------------------------------------------------------
Stack-id
Status
------------------------------------------------------------------------
0
online
NOTE:
In the User-Configured Cascade Ports field, A (active) indicates that a C9010 port is up (no shutdown) and configured
as a cascade port; I (inactive) indicates that a port is down and configured as a cascade port.
Dell# show interface port-channel brief
Codes: L - LACP Port-channel
O - OpenFlow Controller Port-channel
A - Auto Port-channel
LAG
Mode
Status
A
258
N/A
up
Next Steps
After you complete the initial provisioning, you can configure L2 software features on the N30xx system from the C9010 console CLI,
including LLDP, 802.1x, LACP, loop detection and BPDU Guard. No other L2 protocols are supported. IP address and L3 protocol
configuration on N30xx ports are not supported. For detailed information, see the Dell Networking Configuration Guide for C9000 Series
Switches.
When the N30xx system is online, you can enter the connect pe pe-id command on the C9010 console to remotely log in to the
N30xx CLI. To log in, enter the user name peadmin and the password calvin. After logging in, you can enter show and stack
renumbering commands on the N30xx system.
Type
1
N3048P
Reason
Type
-
N3048P
Uptime
14:45:26
--
System-MAC
34:17:eb:00:bb:22
UnitMac
34:17:eb:00:bb:11
Ports
Te 0/1,2
(up)
No. of Ports
48
Starting and Configuring the N30xx System
47