Dell PowerEdge M600 Используйте руководство - Страница 27
Просмотреть онлайн или скачать pdf Используйте руководство для Переключатель Dell PowerEdge M600. Dell PowerEdge M600 44 страницы. Using dell blade servers in a dell poweredge high availability cluster
Также для Dell PowerEdge M600: Руководство по обновлению (44 страниц), Руководство по обновлению (21 страниц), Руководство по обновлению (14 страниц), Руководство по установке (7 страниц)
Cabling the Private Network
The private (heartbeat) network is used for sharing cluster health and status
information between the cluster nodes. Each cluster node connects to the
private network through the second embedded NIC port on the server
module system board. The second NIC port connects to the internal
connections in the system chassis to the second Ethernet switch module or
the associated port in the corresponding Gigabit pass-through module. The
Gigabit Ethernet switch module or Gigabit pass-through module is
connected internally to the private network-configured Gigabit Ethernet
switch module in the private network or the corresponding port on the
corresponding Gigabit Ethernet pass-through module.
NOTE:
It is recommended that you configure the second NIC port on each server
module for the private network.
The Gigabit Ethernet pass-through module connectors correspond directly to
the server module number. For example, server module 2 is connected to port
2 on the Gigabit Ethernet pass-through module. To create a private network
between server module 2 and server module 4 (see Figure 1-1) using a Gigabit
pass-through module, connect a standard Ethernet cable to port 2 and port 4
on the Gigabit Ethernet pass-through module.
Table 2-2 provides a cable connection matrix for configuring the private
network using a Dell PowerConnect™ Ethernet switch or Gigabit Ethernet
pass-through modules in your PowerEdge server enclosure.
Table 2-2. Cabling the Private Network
Module Type
Ethernet switch
module
Cluster Configuration
Two or more nodes in
one PowerEdge server
enclosure.
Two or more nodes in
two PowerEdge server
enclosures.
Private Network Configuration
The private network is established using
internal connections in the system
chassis.
Identify the Ethernet switch module on
1
each PowerEdge server enclosure that is
connected to the private network-
configured adapters on each server
module.
Connect a standard Ethernet cable from
2
the appropriate switch on system 1 to
the appropriate switch on system 2.
Cabling Your Blade Cluster Hardware
27