AVYCON AVC-LHN21SVT-A1S Краткое руководство по эксплуатации - Страница 8

Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Камера безопасности AVYCON AVC-LHN21SVT-A1S. AVYCON AVC-LHN21SVT-A1S 19 страниц. 2mp auto-tracking ptz bullet camera

AVYCON AVC-LHN21SVT-A1S Краткое руководство по эксплуатации

How to perform a Hardware Reset

1. While power is off, press and hold reset button, then power on the camera and the IR LEDs
will begin to flash.
2. There are 2 hardware models of our camera. Please follow instructions for the proper
models below:
Model - A: Keep holding button until the LEDs stop flashing;
Model - B: Keep holding button until the IR LEDs stay on;
3. Release the reset button and the camera will begin the reset process, which should take 1-3
minutes to complete. After the reset process is complete, the camera will have an IP address
of 192.168.10.201. If you find that the IP address has not changed, please repeat process
from Step 1.
4. If needed, modify the IP address of the camera using the Tools utility.
How to Connect to a Alarm Interface
General I/O
Terminal Block
PIN1: Alarm Output NC / NO 24V DC 1A
PIN2: Alarm Output NC / NO 24V DC 1A
PIN3: Alarm Input NC / NO ≤12V
PIN4: Alarm Input NC / NO ≤12V
6
2MP AUTO-TRACKING PTZ BULLET CAMERA | AVC-LHN21SVT-A1S
Digital Output
PIN1
PIN2
Digital Input
PIN3
PIN4