Miele DA 2900 Инструкции по эксплуатации и установке - Страница 6

Просмотреть онлайн или скачать pdf Инструкции по эксплуатации и установке для Вентиляционная вытяжка Miele DA 2900. Miele DA 2900 40 страниц. Cooker hood

Miele DA 2900 Инструкции по эксплуатации и установке
Warning and Safety instructions
~
During installation, maintenance and
repair work, the appliance must be
disconnected from the mains electricity
supply.
~
Do not connect the appliance to the
mains electricity supply by a
multi-socket adapter or an extension
lead. These do not guarantee the
required safety of the appliance (e.g.
danger of overheating).
~
For appliances with an external fan
motor (...EXT models) the connection of
the two units must be made using the
connection cable and the plug
connectors.
These models may only be combined
with a Miele external motor.
~
The appliance must not be used in a
non-stationary location (e.g. on a ship).
~
In areas which may be subject to
infestation by cockroaches or other
vermin, pay particular attention to
keeping the appliance and its
surroundings in a clean condition at all
times. Any damage which may be
caused by cockroaches or other vermin
will not be covered by the guarantee.
6
Using at the same time as other
heating appliances that depend on
the air from the room
Warning - danger of toxic fumes
~
Great care should be taken when
using the cooker hood at the same time
and in the same room or area of the
house as another heating appliance
which depends on the air in the room.
Such appliances include gas, oil, wood
or coal-fired boilers and heaters,
continuous flow or other water heaters,
gas hobs, cookers or ovens which draw
air in from the room and duct exhaust
gases out through a chimney or
extraction ducting.
When used in extraction mode, with or
without an external motor fitted, the
appliance draws air in from the room in
which it is installed and from
neighbouring rooms.
If there is insufficient air, an
underpressure will occur. The heating
appliance may be starved of oxygen,
impairing combustion.
Harmful gases could be drawn out of
the chimney or extraction ducting back
into the room, with potentially fatal
consequences.