Miele DDF 125 Руководство по установке - Страница 13
Просмотреть онлайн или скачать pdf Руководство по установке для Вентиляционная вытяжка Miele DDF 125. Miele DDF 125 28 страниц. External motor roof installation
Также для Miele DDF 125: Руководство по эксплуатации и установке (24 страниц), Инструкции по эксплуатации и установке (28 страниц)
Feed the flexible ducting through the
telescopic wall pipe and secure it to
the collar on the motor unit fixing
bracket with a hose clip.
Secure the bracket to the external
wall with 3 screws.
Extend the flexible ducting from the
inside of the wall along the wall pipe
and seal the gap between the ducting
and the wall pipe with jointing
compound.
Refit the motor unit and secure with
the 2 screws on the underside of the
external motor.
Connect the control cable plug
connectors.
Use the extension cable supplied to
lengthen the connection cable if
necessary.
Installation
13