1. With the temperature control knob set at 230°F, heat the empty kettle until the vacuum/pressure gauge
indicates 5-10 psi.
Caution - do not exceed 5 - 10 psi. Opening the safety valve at higher pressures is a severe burn
hazard.
2. Release steam and air from the steam/water jacket by lifting the lever on the safety valve to allow air to escape.
The pressure will drop to 0 psi.
3. Repeat the process several times until steam and droplets of water exit consistently from the safety valve.
TEMPERATURE LESS THAN 125 F
WITHOUT AIR IN KETTLE
40
20
60
0
80
100
30
Hg
PSI

MAINTENANCE

Caution: Be sure the main power supply switch is "OFF" before cleaning and/or servicing.
Caution: Use of any replacement parts other than those supplied or authorized by manufacturer voids all
warranties, and can cause bodily injury to the operator and damage to the equipment.
Service performed by other than factory authorized personnel will void all warranties.
Warning: The control box is not waterproof. Care must be exercised to keep water and cleaning solutions out
of the box. Never hose or spray electrical controls, connections or control console.
Warning: Never allow water or food stuff to come in contact with any electrical components when cleaning
and/or cooking.
Before operating, the unit must be washed with mild detergent and rinsed thoroughly with water.
The stainless steel surface of the unit may be polished with any reputable commercial stainless steel cleaner or
polish. Do not use any abrasive materials or metal implements that might scratch the surface, because scratches
make the pan hard to clean and provide places for bacteria to grow. Do not use steel wool, which may leave
particles imbedded in the pan surface and cause eventual corrosion and pitting.

SERVICE

Caution: Be sure the main power supply switch is "OFF" before cleaning and/or servicing.
Caution: Use of any replacement parts other than those supplied or authorized by manufacturer voids all
warranties, and can cause bodily injury to the operator and damage to the equipment.
Service performed by other than factory authorized personnel will void all warranties.
The kettle's steam/water jacket should now be free of air. At room temperature,
the pressure gauge should rest at approximately 25 Hg, indicating a vacuum in
the kettle's jacket. To check the gauge for proper vacuum after venting, the
temperature can be quickly reduced by filling the kettle with cold water.
If the kettle will not hold a vacuum, have a qualified service technician test for
leaks at the safety valve, the vacuum/pressure gauge and the water fill fittings.
We suggest mixing a 50/50 solution of liquid detergent and water while heating
the kettle to at least 5 psi pressure. Then, shut off power to the kettle.
The soapy solution should be applied to the suspected area while the gauge
shows at least 5-psi pressure. Any bubbles, which appear, will indicate a leak.