5 PC Online Operation
5.1 Single Processor Communication Link with PC:
Multi-types as USB, RS232, WIFI etc.
IN-A
MUTE
Note: The ID of User Interface should be the same as the
processor in order to the succeed online.
5.2 Multi Processors Communication Link with PC: RS485
®
Use USB-RS485 convertor and Cat 5e cable to connect PC with
RS485-IN interface of the first device. The first processor must be
Master Mode, the other must be Slave Mode.
®
Use Cat 5e cable to connect RS485-OUT interface of the first
device with RS485-IN interface of the second device.
®
Use Cat 5e cable to connect RS485-OUT interface of the second
device with RS485-IN interface of the third device.
®
As step 3, use Cat 5e cable to connect multi devices. One PC can
be connected with three models of device ( 4 in 8 out, 2 in 6 out, 2
in 4 out) . The maximum number of connections are 32 processors.
®
Finally, RS485-OUT of the last device is connected with the
terminal resistor via Cat 5e cable.
Note: 1. For the same model processor, each device ID should
be set differently.
2. Only main controlling processor must be Master mode
in all. processors.
USB
PC
RS485 IN
RS485 OUT
About the UI Operation, please refer to UI software manual.
5.3
5.4 WIFI Online Operation
5.4.1 Connect Mode:
Select one as master device, WIFI mode set to Master Mode, the other
devices select as Salve Mode.
Connect RS485 Input Port on Salve device to Output Port on Master
device.
The rest devices will be connected the same method until all device
are in the Network.
5.4.2 Operation on IPAD:
Turn on IPAD
WIFI
to connect the Master Devie to the correspond
wireless network, then open APP to control the unit on
The default network name for master device is DS428E.
CLIP
+12
MA DE IN CHINA
+6
0
-6
-12
-24
RS232
MA DE IN CHINA
RS232
RS485 IN
RS485 OUT
max 32 pcs
RS485 IN
RS485 OUT
terminal resistor
IPAD
.
5.4.3 Download APP from Apple Store
1.Install App:
Search DIGISYNTHETIC in App Store on IPAD. Download
DIGISYNTHETIC MULTI DS SERIES CONTROLLER and complete
download process.
2.WIFI Connection:
1.Turn on the power, select
2.Set on iPad ->Wi-Fi->Connect
network(Default
WIFI
SSID is 428E), and connect to the network.
P.S. : Stable
WIFI
singal distance is within 30 meters.
3.App Control
(1) Search the current access network device.
(2) Select online device.
(3) Switch to the operated device(s).
7
WIFI m
ode on the control panel .
WIFI
Search 428E
WIFI