13. Load 200 sheets of 100gsm A4 non-coated into Tray 1
14. Wait till the Pro C900 / Pro C900s comes to idle, then print out the
15. Check the version of system software and update if necessary.
Important:
16. Update all mainframe firmware modules.
Important:
17. Remove all peripherals from their packaging and follow each
18. While referring to the Pro C900 / Pro C900s service manual and
19. Update all peripheral firmware modules.
Important:
Colour High Volume Production System - Installation Guide
Pro C900
full SMC report. Keep this initial SMC report with the machine
throughout the run-up and installation process.
Note: Do not use this version of the SMC as the final version.
Load any patches that may be required.
When updating firmware on the Pro C900 and Pro C900s
mainframe please only update one firmware module at a
time.
Download all the latest machine and peripheral firmware modules
from the Ricoh Technical Website/ Firmware/ Pro C900 - Pro
C900s.
Please use the following links to download the firmware:
Pro C900:
http://partners.ricoh.com.au/web/aubase/technical/software.nsf/w
ebfirmwarebyprod?Openview&RestrictToCategory=AFICIO PRO
C900
Pro C900s:
http://partners.ricoh.com.au/web/aubase/technical/software.nsf/w
ebfirmwarebyprod?Openview&RestrictToCategory=AFICIO PRO
C900S
The Perfect Binder should be delivered to site still in its
packaging/pallet. Do not run the Perfect Binder up in the
workshop and then ship to the customer's site. This is
because the run down and run-up procedure is very
complex and time consuming.
peripheral's run-up procedure as instructed in the relevant service
manual.
the order of installation information found in this document,
configure all options to the mainframe. Make sure that the correct
entrance guides and mounting brackets are installed.
Ensure that ALL of the latest mainframe firmware modules
are installed before updating each peripheral's firmware.
Each peripheral's firmware must be updated in the correct
order starting from the option closest to the mainframe.
An error could occur when an update is attempted by
selecting multiple peripheral firmware modules at the same
time. Always update each peripheral's firmware one
peripheral at a time. Failure to do this may lead to the
replacement of the BCU board.
Page 14 of 24