Actulux HCV Series Руководство по эксплуатации - Страница 10

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Приводы постоянного тока Actulux HCV Series. Actulux HCV Series 12 страниц. Chain drive

Actulux HCV Series Руководство по эксплуатации
HCVA/HCVAR
Bracket set HMB-HCV-03 for Skylight
Note!
The top bracket has to be
mounted straight (parallel) or tilted to the left
side, to keep tension at the back of the chain.
2
3
2
3
4
5
Stroke
350 mm
600 mm
This Document contains proprietary data of Actulux
A/S. No information, reproduction or use of any part
there of may be used without written permission.
Tolerances unless otherwise specified: ISO 2768-mL.
Distance between holes +/- 0.2mm and
Maximum stroke lenght for
diameters +/- 0.1mm. Ri = 1mm for bending
ISO 13920-BH for welding processes
SURFACE TREATMENT/FINISH:
this application is 600 mm.
-
WEIGHT:
0.863 KG.
DRAWN BY: GS
DATE: 15-10-19
4
5
6
7
X
227 mm
352 mm
Actulux A/S
Phone int.: +45 98 57 40 90
Haandvaerkervej 2
Fax int.:
+45 96 15 28 00
DK 9560 Hadsund
Denmark
www.actulux.com
MATERIAL:
SIZE:
SHEET:
A3
1 OF 1
Material <not specified>
DWG NO.:
TITLE:
HCV 500/350 - 24/36/48VDC
31010100_33010102
w Bracket Set 33010102
6
7
10
8
A
B
C
D
E
SCALE:
1:2
F
REV:
8
#33010102