TECHNICAL SPECIFICATIONS
Environmental Specifications
The environmental specifications for the 5108 blade chassis are listed in
Table 27 UCS 5108 Blade Server Environmental Specifications
Parameter
Temperature operating
Temperature nonoperating
Altitude operating
Humidity operating
Humidity nonoperating
Vibration nonoperating
Shock operating
Shock nonoperating
Safety
Emissions
Immunity
Electrostatic discharge
Acoustic
48
Minimum
10°C to 35°C (50°F to 95°F)
-40°C to 65°C (-40°F to 149°F)
0 to 3, 000 m (0 to 10,000 ft.); maximum ambient temperature decreases
by 1° per 300 m
10 to 90%, non-condensing
5 to 93%, non-condensing
2.2 Grms, 10 minutes per axis on each of the three axes
Half-sine 2 G, 11 ms pulse, 100 pulses in each direction, on each of the
three axes
Trapezoidal, 25 G, two drops on each of six faces ΔV: 175 inches per second
each corner on bottom face drop, 90 inches per second each corner on
other five faces
UL60 950-1 No. 21CFR1040, CAN/CSA-C22.2 No. 60950-1, IRAM IEC60950-1,
CB IEC60950-1, EN
60950-1, IEC 60950-1, GOST IEC60950-1, SABS/CB IEC6095-1, CCC*/CB
GB4943-1995, CNS14336, CB IEC60950-1, AS/NZS 60950-1, GB4943
47CFR Part 15 (CFR 47) Class A, AS/NZS CISPR22 Class A, CISPR2 2 Class A,
EN55022 Class A, ICES003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3,
KN22 Class A, CNS13438 Class A
Verified to comply with EN55024, CISPR 24, KN 61000-4 Series, KN 24
Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to 8 kV
contact discharge without physical damage
Sound power: 68.8 dBA at ambient temperature 23° C measured using
■
the Dome Method
GOST MsanPiN 001-96
■
Table
27.
Cisco UCS 5108 Blade Server Chassis