Также для Epson ProofPlus TM-H6000III: Руководство по эксплуатации (27 страниц), Брошюра (2 страниц), Технические характеристики (2 страниц), Брошюра (6 страниц), Руководство пользователя (32 страниц), Руководство по разработке (26 страниц), Руководство по разработке (45 страниц), Руководство (10 страниц), Руководство пользователя (29 страниц)

Epson ProofPlus TM-H6000III Руководство по разработке
Error events to be fired when "Issue an Error Event for every error
occurrence during Check insertion." radio button of "Error handling options
during Check insertion setting." in "Device Specific Setting" dialog box is
marked.
ResultCode
OPOS_E_ILLEGAL
*1
Unsupported by the TM-U950.
*2
Error event to be fired when "Fire ErrorEvent on check digit parity error." check box in "Device
Specific Setting" dialog box is marked.

6.2 Remedial Actions for Principal Errors

ResultCodeExtended
OPOS_EX_DEVBUSY
OPOS_EX_TIMEOUT
OPOS_EPTR_COVER_OPEN
OPOS_EPTR_JRN(REC)_EMPTY
OPOS_EPTR_CUTTER
OPOS_EPTR_UNRECOVERABLE
OPOS_EPTR_AUTORECOVERABLE
OPOS_EPTR_MECHANICAL
OPOS_EMICR_COVEROPEN
OPOS_EMICR_JAM
OPOS_EPTR_REC_CARTRIDGE_REMOV
ED
OPOS_EPTR_REC_CARTRIDGE_EMPTY
OPOS_EPTR_REC_HEAD_CLEANING
OPOS_EX_INVALIDMODE
OPOS_EX_BADPARAM + x
OPOS_EMICR_NOCHECK
OPOS_EMICR_CHECK
OPOS_EMICR_BADDATA
OPOS_EMICR_DATAERROR
OPOS_EMICR_BADSIZE
OPOS_EMICR_NODATA
OPOS_EX_DISPOSE_ERROREVENT
ResultCodeExtended
OPOS_EMICR_DATAERROR
OPOS_EMICR_DIGITERROR
If the power to the MICR(TM Printer) is disconnected, it is
necessary
Open/Claim/Enable again.
Confirm the status of the printer, and then execute the program
and method again.
Establish the condition where processing can be executed, and
execute again.
The parameter is not correct for the method to be used. Confirm
the parameter range for the method to be used.
A Check is inserted/removed incorrectly. Confirm the check is
inserted/removed correctly.
Check data error. Once remove it, then insert again, or use a
proper check.
The event processing is not complete yet. Execute the event
processing.
23
APPLICATION DEVELOPMENT GUIDE
MICR (EPSON TM Series)
Version 3.00 Feb. 2019
Meaning
*1
The read data contained not analyzable data.
*2
Data format is illegal.
(
Check of check digits failed.)
Remedy
to
once
apply
Close
and
then