23. Turn the Outer Pointer counterclockwise.
• Set both Pointers to zero.
24. Install Shroud (27) [notch downward] onto the
Housing.
25. Install Screws (28) that secure the Shroud to the
Housing.
• Tighten each Screw securely.
Lever Assembly
26. Install Quad Rings (38) onto each end of Cam
(39).
27. Install the Cam into the Housing.
• Use care passing the Quad Rings.
28. Install Lever Assembly (41) onto the Cam.
• Reposition the Cam as required to ensure the
Lever Assembly properly meshes.
29. Install Screws (40) that secure the Lever
Assembly to the Cam.
• Tighten the Screws securely.
Valve and Inlet Swivel Assembly
30. Install Valve Sleeve (37) [unslotted end first] into
the Housing.
31. Install Valve Assembly (36) [stem first] into the
small end of Spring (35).
32. Install the Valve Assembly and Spring
horizontally into the Housing.
• Make sure the Valve Assembly does not shift.
33. Install Screen (34) into the Spring.
34. Install O-Ring (33) onto the Adapter (32).
35. Screw the Adapter into the Housing.
• Tighten the Adapter to 20 ft. lbs. (26 Nm).
36. Screw Swivel Assembly (9) [with thread sealant]
into the Adapter.
• Tighten the Swivel Assembly securely.
Extension
IMPORTANT: Apply thread sealant to
all pipe thread connections prior to
assembly.
37. Connect the components of the extension
assembly and tighten securely.
38. Screw the extension assembly into Meter
Assembly (8).
• Tighten the extension securely.