AlphaVision 16 Руководство пользователя - Страница 3
Просмотреть онлайн или скачать pdf Руководство пользователя для Панель управления AlphaVision 16. AlphaVision 16 12 страниц.
GENERAL INTRODUCTION
This manual is meant for the user of the AlphaVision 16 and AlphaVision 96 control panels.
The technical term for a control panel is "intrusion detection system" . This is exactly where
we developed the AlphaVision 16 and 96 for, namely detecting burglary. The AlphaVision 16
and 96 can also be used for detecting fire, hold-up, sabotage and technical alarms.
The heart of this protectionsystem consists of an advanced elecktronic device in a metal box,
which has been installed professionally by an engineer. This device is called the "control
panel". Detectors will be linked to this control panel. Sometimes a detector is called "sensor"
or "eye". A detector is a device, designed to observe a certain phenomenon. For example to
observe fire. As soon as this detector observes a fire (smoke), this detector will communicate
this to the control panel. The control panel will take further actions, for example dailing a
telephone number and give an alarmsignal.
For the observation of fire are no actions neccesary. When a fire- or smoke detector has been
installed by an engineer the control panel will, as soon as the detector has given a signal, give
an alarm.
In case of burglary, things are different. Sometimes it is allowed to walk around in the protec-
ted building (in the daytime) and sometimes it is not allowed. So the control panel must know
when it must come in action. To realize this, there must be ARMED and DISARMED.
Arming the control panel means: there are no persons allowed to be in the building. If there
are people in the building, they are supposed to be unauthorized persons and it will be handled
as burglary. Is the contol panel disarmed, then people are allowed to walk around freely.
Most important differences between the AlphaVision 16 and AlphaVision 96
Maximum amount of zones:
Maximum amount of sections:
Maximum amount of usercodes:
The display of the keypad shows the sections in characters, for the AlphaVision 96 the characters A to H are used
and for the AlphaVision 16 A to D are used. Dividing the system in sections is used as follows:
A house with 16 zones is divided in 4 sections: e.g. the zones 1 to 6 belong to section A (downstairs), zones 7 to
12 belong to section B (1st floor), zones 13 and 14 belong to section C (garage) and zones 15 and 16 belong to
section D (loft). If the inmates go to sleep, the sections A, C and D must be armed. If they leave the house all
sections must be armed (other combinations are also possible).
It is also possible to have zones which belong to more than one section. These zones are armed if all sections to
which they belong are armed.
The examples used in this manual are all based on the AlphaVision 96
User manual AlphaVision 16/96 *** 21 augustus 2003 ***
AlphaVision 96
AlphaVision 16
96
8
98
16
4
40
Page 3