Bypassing zones

It is possible with the AlphaVision 16 or AlphaVision 96 to bypass zones. In fact this means that the operation of
a detector will be bypassed. This is only neccesary in very special cases, for example if a detector is damaged
during a rebuilding. In such situations it is not possible to arm the AlphaVision 16 or AlphaVision 96 because the
zone will stay open by the damaged detector. To make arming possible the zone must be bypassed.
Zones will be bypassed by pushing <
followed by the zone number in one or two digits,
followed by <#>,
followed by a PIN-code of level 4 or 5.
The following message appears on the display:
Zone bypassed
zone name
In stead of "zone name", normally a real programmed zone name will be displayed, for example: "front door".
If one or more zones are bypassed and a usercode (PIN-code) is entered, the keypad will show the following
message:
Some zones are
bypassed! <#>
The bypassing of a zone will be cleared if the above mentioned action will be executed again. The bypassing of a
zone will be cleared automatically if the section to which the zone belongs has been armed and then disarmed.
Bypassing a zone is only valid for one time, to prevent that a zone is bypassed for a long time.
It is possible that the installer programs the control panel so that some very important zones cannot be bypassed.
In that case the display shows "bypass of zone not allowed".

EXECUTING FUNKTIONS

Functions entering

Each function of the AlphaVision 16 or AlphaVision 96 will be executed by pushing <?>, followed by <1 or 2
digits>, followed by <#>.
As soon as this has been entered, the display shows at the lower line an explanation of the selected function. After
this a user code must be entered. This user code has to be of a sufficient level to execute the function. If for
example a code with level 1 is entered (the lowest level), the control panel returns immediately to the rest
situation.
Which user level is neccesary for executing a function, is shown in the table below:
F1#
Activating the RESET output
F2#
Doorbell on/off
F3#
Adjust date
F4#
Adjust time
F5#
F6#
Programming users codes
F7#
Start engineermenu on connected PC
F8#
Start up/downloading
F9#
User manual AlphaVision 16/96 *** 21 augustus 2003 ***
Page 6
?
]
>,
This is a warning which has to be accepted by pressing the <#> key.
After pressing the <#> key, the control panel will react like normal.
code level 4, 5 or 6
code level 4, 5 or 6
code level 4, 5 or 6
code level 4, 5 or 6
code level 5
code level 5 or 6
code level 5