Aerial AD 550 Руководство - Страница 8

Просмотреть онлайн или скачать pdf Руководство для Осушитель Aerial AD 550. Aerial AD 550 16 страниц.

Aerial AD 550 Руководство
6.3 Operation panel
On-/Off-switch
neon:
tank full
Operation time
counter
ATTENTION:
Make sure that the ventilation slot next to the operation panel is free and not
covered. The air must be able to flow through this slid.
6.4 Hygrostat control
The air dryers of the AD-series dispose of a hygrostat for setting the required
humidity value. This hygrostat is located in the operation panel of the unit.
It makes that the air dryer cuts in as soon as the ambient humidity exceeds the
preset value. If the humidity value falls below the set value, the hygrostat will switch
off the unit.
The hygrostat is placed in the operation panel laterally at the unit.
Pos. 0
= Unit is switched off
Pos. 1
= Continues operation
80-100% = The dehumidifier switches off
when a humidity of approx.
80 - 95% r.h. has achieved.
And switches on again when
humidity is higher than 80-95%.
60 - 80% = The dehumidifier switches
off when a humidity of approx.
60 - 80% r.h. has achieved.
And switches on again when
humidity is higher than 60-80%.
page 8 of 15
Hygrostat
(see Pt. 6.4)