1 General advice

You have bought an air dryer made by AERIAL thus deciding for a proven quality product
"Made in Germany". If nevertheless complications should occur, you will find some advice
hereinafter how to eliminate such difficulties as quickly as possible.
Attention!
Immediately after receipt, you should check your air dryer for transport damage! In the
case of damage, you should inform the forwarding agent, parcel service, post office etc.
accordingly upon receipt, and make a note of it on the forwarding documents!
If a transport damage should be stated after unpacking the equipment, please contact
immediately your respective seller.
Before putting your air dryer into operation for the very first time, these instructions for
operation should be studied very thoroughly. Thus, you can make sure that this appliance
will operate perfectly for a long period of time saving yourselves unnecessary repairs and
expenses.
In the case of technical unclarity or faults disconnect your appliance and ensure that it is
not connected again by taking the mains plug out of the socket.
Please, keep the device wrapping in order to be able to send the device safe for
guarantee repair. In order to save place you open simply the adhesive tape with a
knife and you fold the carton.

2 Design of equipment and mode of functioning

The AD-air dryer is constructed exclusively for air drying in closed rooms. That dehumidifier
can prevent the formation of sweating water, eliminate too high air humidity and hold a specific
air humidity unchangeable. The time which the dryer requires in order to achieve a specific
humidity depends essentially on the environmental conditions. The attainable humidity value is
equally dependent on the environmental conditions.
The AD-dehumidifier works according to the condensation principle with heat recovery. The
fan (partial positions see detail drawing) suck the moist air through a cool register
(evaporator). The air becomes so far chilled under the point of condensation here, that the
steam of air condense as water and flows into the water-collecting tank. The chilled and dried
air is warmed up at the condenser again. Through the heat pump effect, the outlet air is some
degrees warmer than the sucked room air. Vigour profit can conducted up to 3-fold of the
electrical power consumption. The absolute moisture of air is lowered continuously by the
continuous circulation of the room air through the device. The surplus moisture is removed
takingly and efficiently.
from serie July 2003
1
- wet room air
2
- dry air
3
- evaporator (cooling)
4
- condenser (warm up)
5
- condensate (in tank)
6
- compressor
7
- fan
page 2
AERIAL GmbH