ARTRAY ARTCAM-036MI2 Series Буклет с инструкциями - Страница 18

Просмотреть онлайн или скачать pdf Буклет с инструкциями для Цифровая камера ARTRAY ARTCAM-036MI2 Series. ARTRAY ARTCAM-036MI2 Series 20 страниц. Usb2.0 cmos camera

8-2-2 Trigger timing chart (ARTCAM-130MI/300MI series)
t0
Trigger Input
TRIG Signal
Reset Time
Exposure Time
st
1
Line
nd
2
Line
Last Line
Vertical Synchronization Signal
Image Transfer (USB)
t0
Input Pulse Width
t1
Photo Coupler Delay
t2
Reset Time
t3
Exposure Time
t4
Frame Transfer
t5
Effective Trigger for next frame
*For ARTCAM-130MI/300MI, the image will be acquired only when the trigger signal transits from a high
voltage to a low one. If the trigger signal stays at a high level or at a low level, no image will be acquired.
t1
t2
t3
t4
t5
Above 1ms
1~99μs (Subject to Input Pulse Voltage)
9 * 1H(ARTCAM-130MI series)
18 * 1H(ARTCAM-300MI series)
Subject to Shutter Speed Settings
Subject to ROI Settings and Operation Clock
Approximate 100H after the Vertical Synchronization Signal
transits to a low voltage
- 18 -