3M 6200 Краткое руководство по эксплуатации - Страница 2

Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Респираторный продукт 3M 6200. 3M 6200 2 страницы. Half facepiece respirator
Также для 3M 6200: Инструкции пользователя (16 страниц), Технический паспорт (3 страниц), Краткое руководство по эксплуатации (2 страниц), Краткое руководство по эксплуатации (2 страниц), Краткое руководство по эксплуатации (2 страниц), Инструкции пользователя (2 страниц)

3M 6200 Краткое руководство по эксплуатации
Step 3: Filter Assembly Connection to Facepiece
1. Align mark on back
side of 7093 fi lter with
facepiece mark in
order to properly align
fi lters.
Step 4: Donning Respirator & Adjusting Fit
1. Place the respirator
over your mouth and
nose and pull head
harness over the
crown of head.
Adjust the straps so the respirator is comfortable and snug, but do not overtighten.
Note: Decrease strap tension by pushing out on back side of buckles.
Note: Use of the EVF does not change donning steps.
If you have questions, consult your supervisor or call 3M Technical Service at 1-800-243-4630 (USA) or 1-800-267-4414
(Canada).
Notice: These respirators are not FDA cleared for use as a medical device.
Medical Solutions Division
3M Health Care
2510 Conway Ave.
St. Paul, MN 55144 USA
2. Rotate fi lter ¼ turn
clockwise until it is
fi rmly seated. Repeat
steps 1-2 for second
fi lter.
2. Connect the bottom
straps at the back of
the neck.
Step 5: Positive Pressure User Seal Check
Place the palm of your hand over the exhalation valve cover (if using the EVF
place the palm of your hand over the EVF opening) and exhale gently. If
facepiece bulges slightly and no air leaks are detected between your face and
the facepiece, a proper seal has been obtained. If faceseal air leakage is de-
tected, reposition respirator on your face and/or readjust tension of the elastic
straps to eliminate leakage. If you cannot achieve a proper seal, DO NOT
enter contaminated area.
Phone: 1-800-228-3957
Web: 3M.com/Medical
Facepiece with 7093
fi lters properly attached.
Note: Rotate fi lters
counterclockwise to
remove.
3. Adjust top straps by
pulling on ends of
straps.
©3M 2021. All rights reserved. 3M and the other marks
shown are marks and/or registered marks. Unauthorized
use prohibited. Used under license in Canada.
GL_70-2011-7961-4
4. Adjust bottom straps
by pulling on ends of
straps.