ASI 0144 Руководство по эксплуатации - Страница 2

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Сушилка ASI 0144. ASI 0144 6 страниц. Surface-mounted automatic hand dryer

Hand Dryer

General safety information:

This product is intended
for installation by a qualified service person.
Use AWG NO. 12 solid conductor for wiring.
Failure to properly ground
unit could result in severe electrical shock
and/or death.

Installation

1. Make sure power supply breaker is switched off. Installation must be carried out in accordance
with the current edition of the local wiring regulations code having jurisdiction. Installation should
be performed only by a qualified electrician.
2. Place template against wall at desired height (see mounting height recommendations) and mark
locations of 4 mounting holes and wire service entry at knockout (KO) location.
Note: For two or more dryers, dryers should be no closer than 24 inches (610 mm) on center.
3. Remove and retain 2 cover screws and cover.
4. For in-wall (concealed) power supply - Provide supply wire to KO location according to local code
and attach securely to chassis at KO with appropriate strain relief connector (not supplied).
5. Attach dryer to wall. For wood wall/studs use ¯1/4 inch (M6) screws at length that will ensure
1 inch (25 mm) min. stud penetration. For masonry walls use expansion bolts or anchors for ¯1/4 inch
(M6) screws to ensure penetration 1/4 inch (6 mm) deeper than anchor. Shim if necessary to
ensure base plate is flat against wall.
6. Connect supply and ground wires to terminal block where indicated or connect supply wires to terminal
block where indicated and connect ground wire to base plate with ground screw (Connections: A.
Connect the live wire (colored Brown or Black) to the terminal block marked "L1". B. Connect the
neutral wire (colored White or Grey) or connect the second live wire (colored Red or Orange) to the
terminal block marked "N/L2". C. Connect the ground wire (colored green or green and yellow or bare
conductor) to the terminal block marked "
neutral wires depend on voltage of supply service and requirements of Building and Electrical Code
having jurisdiction.
7. Replace cover. Do not over-tighten screws.
Installation Kit Included (find in carton)
1. Self-Threading screws 1/4" x 2-1/2" (M6 x 64) x 4 pcs
2. Security hex wrench 5/32" (4) L-Type x 1 pcs
06092857
Operating Instructions and Parts Manual
Surface-mounted Automatic hand dryer
-- N
OTE: Do not install dryer over washbasin
service breaker before installing or servicing.
with a 3-wire service. The ground wire must
be connected to the dryer's backplate.
" or to the green screw marked "
2
Disconnect power at the
All units must be supplied
--
"). Colors of live and
www.americanspecialties.com