Ambient Weather WS-14 Руководство пользователя - Страница 14
Просмотреть онлайн или скачать pdf Руководство пользователя для Термометр Ambient Weather WS-14. Ambient Weather WS-14 17 страниц. Wireless 8-channel floating pool and spa thermometer with daily min/max display
To return the temperature to the actual or uncalibrated measurement, press the SET button.
Once the displayed temperature equals the calibrated source, press and hold the SET button for three
seconds, or wait 15 seconds for timeout, and the temperature value will stop flashing.
Discussion: Temperature errors can occur when a sensor is placed too close to a heat source (such
as a building structure, the ground or trees).
To calibrate temperature, we recommend a mercury or red spirit (fluid) thermometer. Bi-metal (dial)
and other digital thermometers are not a good source and have their own margin of error. Using a local
weather station in your area is also a poor source due to changes in location, timing (airport weather
stations are only updated once per hour) and possible calibration errors (many official weather stations
are not properly installed and calibrated).
Place the sensor in a shaded, controlled environment next to the fluid thermometer, and allow the
sensor to stabilize for 48 hours. Compare this temperature to the fluid thermometer and adjust the
console to match the fluid thermometer.
6 Glossary of Terms
Term
Accuracy
Range
7 Specifications
7.1 Wireless Specifications
Line of sight wireless transmission (in open air): 150 feet, 100 feet under most conditions.
Frequency: 433 MHz
Update Rate: 60 seconds
7.2 Measurement Specifications
The following table provides specifications for the measured parameters.
Measurement
Indoor Temperature
Pool Float Temperature
7.3 Power Consumption
Base station (display console) : 3 x AAA 1.5V Alkaline or Lithium batteries (not included)
Remote sensor : 4 x AAA 1.5V Alkaline or Lithium batteries (not included)
Battery life: Minimum 12 months for base station with one sensor and excellent reception.
Intermittent reception and multiple sensors may reduce the battery life.
Minimum 24 months for water sensor (use lithium batteries in cold weather climates less than
-4 °F)
Version 1.1
©Copyright 2014, Ambient LLC. All Rights Reserved.
Accuracy is defined as the ability of a measurement to match the actual
value of the quantity being measured.
Range is defined as the amount or extent a value can be measured.
Range
32 to 140 °F
-40 to 140 °F
Definition
Accuracy
± 2 °F
± 2 °F
Resolution
0.1 °F
0.1 °F