ACR Electronics OLAS GUARDIAN Краткое руководство по эксплуатации - Страница 12

Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Система безопасности ACR Electronics OLAS GUARDIAN. ACR Electronics OLAS GUARDIAN 16 страниц.
Также для ACR Electronics OLAS GUARDIAN: Тестирование (2 страниц), Устранение неполадок (2 страниц)

ACR Electronics OLAS GUARDIAN Краткое руководство по эксплуатации

9. LOW BATTERY ALERT

A low battery alert will be initiated by the Guardian when an OLAS Tag's battery level goes below 20%
The alert is indicated by a red flash every 10 seconds on the control switch and the Guardian Hub
The alert will remain until the battery is changed
You can check which OLAS tag has low battery using the OLAS app
Once you have located the tag you can either:
1.
pause the Guardian, change the battery and restart tracking
2.
or switch off the Guardian to remove the OLAS tag from the log, switch off the OLAS tag and restart
the Guardian
10. GUARDIAN OVERRIDE
When an OLAS transmitter goes out of range an alert will sound, the control switch will flash red and
as a default setting the engine will cut-off
After 5 seconds the engine can be started again so a rescue can be performed
Press the control switch once to stop the alarm and pause the tracking
Once the OLAS transmitter is back on the vessel and within 1 meter of the Guardian, press the
control switch once and tracking will continue
Pause will remain active if the OLAS transmitter that was lost is not back within 1 meter of the
Guardian
11. SWITCHING OFF THE GUARDIAN
The Guardian can be switched off at any point by pressing the control switch for 4 seconds
The control switch will illuminate red with a sound signal before switching off
12. OPERATING WITHOUT OLAS TRANSMITTING DEVICES
When switched ON the Guardian will automatically scan for OLAS transmitters within 1 meter
If no transmitters are found within 30 seconds, the Guardian will emit an alert sound every second
To override the Guardian, press the control switch for 4 seconds which will switch the Guardian off,
your vessel will now operate normally.
WARNING: the cut-off switch and alarm will not operate!
ALWAYS WEAR A TRADITIONAL KILL CORD
13. RECOMMENDATIONS
Switch off your OLAS transmitter if it is not going to be used for longer than 24 hours
Check the battery life of the OLAS tags in the OLAS mobile application before you leave
Check your OLAS Float-On's battery status before your journey and charge if required
12