Installation
Power Requirements
The 7551 requires 0.215A @ 5Vdc. Add this
to the current requirements of your system
when sizing the system power supply. Note
that this requirement excludes the use of some
modules with the 7551 in fixed SLC 500
systems.
Velocity Response Setup
A jumper on the 7551 determines how often
the module updates the velocity data. With the
jumper installed velocity data updates every
120 mSec. Removing the jumper sets the
velocity update to 32 mSec. The figure below
shows the placement of the jumper on the
7551 module.
Velocity Response Jumper
Installed: 120 mSec Update Time
Removed: 32 mSec Update Time
Shown with Jumper installed.
U2
2
LDT I
JP1
JP1
M
NTERFACE
ODULE
Rack Installation
You can install the 7551 in any free slot as
long as power requirements are met. Align the
modules' circuit board with the top and bottom
card guides in the rack and gently slide the
module into the rack until the top and bottom
latches secure the module in place.
To remove the module, depress the top and
bottom latches and slide the module out of the
rack.
Compatible Transducers
The 7551 is designed for use with AMCI's
LHT Series transducers and has been tested
with Temposonics II and Balluff LDTs.
Temposonics II LDTs must have an RPM or
DPM Personality Module and Balluff LDTs
must have the 'K2' output / power supply option.
Temposonics DPM Setup
The DPM Personality Module has switches
that set the number of recirculations and the
interrogation type. When using a DPM Mod-
ule, set Switch SW1 to '4' (4 Recirculations)
and SW2 to '8' (External Interrogation).
Transducer Mounting
Refer to the documentation you recieved with
your LDT to properly mount the transducer.
LDT Power Supply
The 7551 requires a ±15 Vdc power supply for
LDT operation. MTS offers a ±15 Vdc @
0.8A supply for use with their transducers.
MTS Part Number is 380017.
UNDER NO CIRCUMSTANCES is the
-15 Vdc supply, commonly marked '-15 V', to
be connected to Power Supply or Earth Grounds.
Doing so can damage the power supply, the LDT,
and the 7551 module.
ADV ANC ED