No or Low Dispersing Air
Manifolded dispersing air pressure set too low: adjust.
Air hose is kinked or cut: repair or replace.
Spray tip is clogged: clean or replace.
Spray tip is damaged: replace.
Air in Liquid Line
Fluid line is not properly attached to pump: replace hose or fitting.
Injector seal is failing: rebuild or replace.
Liquid Drains from Spray Tip
Injector check valve is failing: rebuild or replace.
Liquid line in single point nozzle assembly is damaged or disconnected: replace

8 T60A Posi-pump Troubleshooting

No Liquid
Pump is turned off: turn liquid adjustment screw counterclockwise.
Pump is seized: remove, clean, and rebuild.
Reservoir is empty: fill.
Air pressure is too low: adjust to over 60 PSI.
Bubbles from Injectors
Air seals are leaking: replace.
Exit fitting is leaking: replace.
Liquid Drains from Injector Outlet
Exit fitting is leaking: replace.
Evacuation valve is ineffective: clean or replace.
Biaxial hose is trimmed incorrectly: be sure hose is cut straight with no burrs or
deformities.