Akw 2842246 Kurulum Talimatları Kılavuzu - Sayfa 5

Sıhhi Tesisat Ürünleri Akw 2842246 için çevrimiçi göz atın veya pdf Kurulum Talimatları Kılavuzu indirin. Akw 2842246 8 sayfaları. Shower tray

Position the tray over the desired
location for the shower and outlet
pipe. Mark around the edge of the
shower tray.
220 mm
220 mm
355 mm
355 mm
The waste area must be supported
with additional noggins, 220mm
around the waste. Additional
noggins or joists must be used on
all tray edges and between joists
centres at a minimum of 355mm.
Apply grab adhesive to all the
contact points between the tray,
joists and noggins. Lower the tray
over the waste position and firmly
secure the tray into position and
check all 4 sides are level again.
Order: 01905 823 299
|
orders.akw-ltd.co.uk

Wooden Floor Installation

For 'in' floor installation, cut into
the flooring, taking care not to
cut through supporting joists or
any plumbing or electrical wiring.
355 mm
Install the waste drain trap and
waste outlet pipe. Do not cut into
the joists, always drill through
when connecting to the waste
outlet pipe.
Attach the waste trap to the tray
with the waste clamping ring,
see separate waste instructions.
Apply a waterproof membrane to
the whole of the showering area,
see manufacturers instructions.
Carefully remove the floor
boards and locate the waste
outlet pipe. For 'on' floor
installation, remove the floor
boards around the waste area.
Water test the waste drain trap
for flow and any leaks. Ensure
that the rubber seal is in place.
Remove any debris and ensure
that there are no sharp edges or
raised areas and check levels.
Safety flooring or tiles should
finish flush up to the edges of
the tray and sealed with sealant.
Protect the waste trap and cover
from debris during installation.
Technical Support: 01905 560 219