7
|
Disassembly
7.2

Detaching the encoder from through-hollow shaft

DANGER
Burns caused by heat
The device heats up at high torque. There is a risk of getting burned after use.
a) Avoid overheating the device.
b) Wear suitable gloves.
Ill. 11: Detaching the encoder from the through-hollow shaft
1
Self-locking nut M6 (ISO 10511)
3
Grounding strap
5
Through hollow shaft
7
Torque arm
9
Washer B6.4 for grounding strap (ISO
7090)
Tool
1,6×8 mm
n
n
10 mm
n
Instruction:
a) Loosen the Torx screw at clamping ring. Do not unscrew the screw completely.
b) Loosen the self-locking nut on the torque arm
c) Loosen the cheese-head screw at grounding strap.
d) Slide the encoder off the shaft.