Baumer FLDK 110G1303/S14 Kullanıcı Kılavuzu - Sayfa 16
Kasa Sayacı Baumer FLDK 110G1303/S14 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Baumer FLDK 110G1303/S14 35 sayfaları. Laser copy counter
9
Instructions for use
9.1
Output pulse length and maximum counting rate
On the one hand, the duration of an output pulse must be long enough so that the customer's control
system can process it. On the other hand, the length of the output pulse limits the maximum counting
rate. Because output pulses must not overlap, the interval between edges must be at least as long as one
output pulse length. If the interval is shorter, then this edge will be suppressed meaning that the edge will
not initiate an output pulse.
The following figure illustrates how every other edge is suppressed because of a too long of an output
pulse length.
Manual SCATEC-2
Version 2021-09
Scatec-2
on
a
off
high
p
low
high
p
low
time
www.baumer.com
a
amber edge-LED
output pulse
pulse length p < interval a
output pulse
pulse length p > interval a
some edges are suppressed!
16
Baumer Electric AG
Frauenfeld, Switzerland