Model 5000 Flow Through Humidifier
12
the relative humidity level in the air and work as the main
ON/OFF switch to control the humidifier, regardless of whether
your furnace is on or not.
At the beginning of the heating season it may take sometime to
build up the relative humidity level in your home to the desired
level. For the first few weeks turn the humidistat up high to ensure
the humidifier will turn on with every furnace cycle; after you feel
that you have achieved the desired relative humidity level turn the
humidistat down until it cycles the humidifier OFF. The humidifier
will then work to maintain the relative humidity at that level.
ACHIEVING AND MAINTAINING A HUMIDITY LEVEL
Outside conditions are the primary factor affecting the humidity
level in your home; the colder it gets outside the less moisture the
outside air will have, your home brings in that outside air and the
humidifier will work to add moisture to it. As outside conditions
change the humidity level in your home will change as well.
Other factors which will affect humidity levels in the home
include how many air-changes are occurring, the amount of
people occupying the home, air leaks, the use of showers,
exhaust fans, HRV's, and the use of a fireplaces or wood stoves.
For more information on achieving a humidity level and or
maximizing the output of the humidifier please see the
Maintenance and Trouble Shooting Guide.
SAFELY OPERATING A FURNACE HUMIDIFIER
Proper control of the relative humidity level in the home is key to
ensuring good IAQ (Indoor Air Quality) for your home as well as
protecting against moisture damage.
Although a relative humidity environment of 45-50% may be
desirable, setting your humidistat at that point when outside air
temperatures are below 30°F can cause condensation on
windows and walls. Continued condensation for extended
periods of time may result in structural damage. Use the chart
below as a guide for maximum relative humidity settings at
different outdoor air temperatures.
OUT SIDE AIR TEMPERATURE MAXIMUM RELATIVE HUMIDITY SETTING
-20°F /-30°C
-10°F /-25°C
0°F / -20°C
+10°F/-10°C
+20°F/-5°C
ABOVE +20°F/0°C
If condensation continues to form on windows at these settings
reduce the humidistat setting by successive 5% increments. After
each reduction in setting allow 6 hours for equilibrium to be
reached before readjustment.
If condensation is consistently forming on your windows or if the
relative humidity level being sensed by the humidistat is consistently
different than the relative humidity level in the home then you may
want to consider changing the location where the humidistat is
mounted. If duct mounted, move the humidistat to a central
location, near the furnace thermostat. If after moving the humidistat
the condition persists turn OFF the water supply at the needle valve,
turn the humidistat off and consult a qualified HVAC service person.
When your house is unoccupied for longer than 3 days during
the winter months always set the humidistat down to 15% so that
severe weather during you absence will not result in
condensation which might cause damage in your home.
SHUTDOWN, AND YEARLY MAINTENANCE
BYPASS AIR ADJUSTMENT
Sometimes there can be a static pressure differential that may
cause an excess of air to flow through the bypass tube, causing
less airflow through the distant heat outlets in the house. It may
also blow water off the evaporator bad. In either case the air
damper installed with the bypass collar should by gradually
closed until the condition is corrected. To close the damper
loosen the top screw and lift up on the damper and turn closed
to the desired position. Damper adjustment is another way of
adjusting the amount of humidity being added to the house (the
less air bypassed the less humidity will be added.)
SUMMER SHUT DOWN
At the end of the heating season complete the following steps.
1. Turn the humidistat off.
2. Unplug the transformer.
3. Close off the water supply at the saddle valve.
4. Close the bypass damper.
YEARLY MAINTENANCE AND WINTER START UP
For detailed recommended maintenance schedule refer to the
Maintenance and Trouble Shooting Guide.
At the beginning of the heating season complete the following steps.
1. Inspect the water supply tube, water drainage tube, and
Electrical wiring replace if required
2. Plug in the transformer.
3. Turn on the water supply at the saddle valve and check for
any leaks.
4. Open the bypass damper.
15%
5. Test the operation of the humidifier and check for any leaks
20%
and complete any necessary repairs.
25%
30%
35%
40%
BYPASS AIR ADJUSTMENT, SUMMER