10.7.3 Module P23
Fig. 11 Mounting P23 with clamps
Load level
clamping area
Clamping
0 mm - 458 mm
- long side -
220 mm - 458 mm
220 mm - 300 mm
Clamping
0 mm - 200 mm
- short side -
Table mounting areas clamping for P23
Load level
Load level
lay-in system
Load level II
- long side -
Table lay-in system for P23
8
based on IEC 61215
aleo solar GmbH | Marius-Eriksen-Straße 1 | 17291 Prenzlau | Germany | [email protected]
Quick Reference Manual Rel. 4.7, 08/2020, EN
- Modules can be mounted horizontally and vertically
- Please note the information on snow load (see Chapter 10.6.5)
Load level
Permissible
pressure (test load)
Load level I
1400 Pa 8
Load level II
2400 Pa
Load level III
5400 Pa
Load level I
1400 Pa 8
Permissible
Permissible
pressure (test load)
suction (test load)
2400 Pa
2400 Pa
Permissible
suction (test load)
1400 Pa 8
2400 Pa
2400 Pa
1400 Pa 8
Page 15/20