16- SHOCK ABSORBER
• Remove the back cover.
• Damper pin at the tub is pulled off by pressing on the snaps at the sharp
end.
• Pull out the damper pin. ( Figure 7 )
a
17- TUB INLET HOSE
• Remove the top lid. ( figure 3, 4, 5 )
• Remove the wire clamp on the detergent box connection and the tub and
the water inlet hose.
18- TUB FILTER HOSE
o Remove kick plate, front panel and top plate.
o Remove air hose from the pressure switch.
o Screw off the clamp of tub filter hose at the tub connection.
o Remove spring clamp from the pump connection and cut off the plastic clamp
securing air break hose to the tub.
o Take tub filter hose out.
19- DYNAMIC SYSTEM ASSEMBLY
o Remove kick plate,front panel,top plate and rear panel.
o Tub inlet hose and detergent dispenser are removed with tub filter hose.
o Remove motor and heater cable connections. Take out thermostat bulp.
o Remove tub connections of shock absorbers.
o Take out dynamic system assembly simply by removing the three springs
carrying it.
( Figure 7a )
Figure 7