Andrew 123 Class I Montaj Talimatları Kılavuzu - Sayfa 6
Anten Andrew 123 Class I için çevrimiçi göz atın veya pdf Montaj Talimatları Kılavuzu indirin. Andrew 123 Class I 9 sayfaları. Antenna system
ASSEMBLY AND INSTALLATION
INSTALLING AZ/EL CAP MOUNT ONTO POLE
The AZ/EL Cap is factory preassembled, therefore, no
assembly is required. Before installing AZ/EL Cap onto
ground pole, a concrete foundation should be in place
and cured.
MODEL 611612001 (Fine Tune Option)
Loosen (8) Carriage Bolts and nuts securing the "U"
Bracket to the Top Bracket and "U" Bracket to (2) half
clamps and swivel nut, hex nut (for optional fine tune fea-
ture). (Ref. Fig. 1.0). Install AZ/EL Cap Mount onto
Ground Pole. Equally tighten (4) Clamp Bolts so that
Cap is held stationary on Ground Pole, but can be
swiveled with slight pressure (approximately 2 ft-lbs (2.7
N-m). Retighten and torque (4) Carriage Bolts and nuts
securing "U" bracket to half clamps to 18 ft-lbs (24.4 N-
m). Leave loose (4) Carriage Bolts and Swivel Nut, Hex
Nuts, for fine tune option.
MODEL 611612002 (w/o Fine Tune Option)
Make sure (4) carriage bolts and nuts securing the
(2) Half Clamps to top bracket are loose. (Ref. Fig.
1.1) Place AZ/EL Cap onto Ground Pole and tighten (4)
Half Clamp Bolts to approximately 2 ft-lbs (2.7 N-m) (just
enough to allow AZ Clamp to turn on pole with slight
pressure). Tighten and torque (4) Carriage Bolts and
Nuts in Top Bracket to 18 ft-lbs (24.4 N-m) (loosened
above).
ASSEMBLING REFLECTOR ONTO AZ/EL CAP MOUNT
96cm System
Install two M8 x 56 (56 mm) Plow Bolts into holes in
Reflector Face and two (91 mm) into bottom holes.
Lift Reflector and insert exposed portion of bolt into
holes into Antenna Bracket Flange. Install 4 Lock
Washers and Hex Nuts on bolts. (Ref. Fig. 1.2)
1.2m System
Install four M8 x 91 (91 mm) Plow Bolts into top holes
in Reflector Face. Lift Reflector and insert exposed
portion of bolt to holes in Antenna Bracket Flange.
Install 4 Lock Washers and Hex Nuts on bolts. (Ref.
Fig. 1.2)
Assemble Extension Plate to AZ/EL Housing using
two M6 x 22mm Round Head Square Neck Bolts,
Lock Washers, and Hex Nuts. (Ref. Fig. 1.3) Tighten
and torque to 6 ft-lbs (8 N-m).
Tighten and torque Reflector bolts to 11 ft-lbs (15 N-m).
IMPORTANT: Note orientation of bolt holes in Reflector
Flange. Holes should be located on each side and bot-
tom of the Reflector as shown in Figure 1.2.
TOP BRACKET
"U" BRACKET
HEX NUT,
CARRIAGE BOLT (8)
HEX NUT
HALP CLAMP (2)
SWIVEL NUT
CLAMP BOLTS
(CARRIAGE BOLT &
HEX NUT) (4)
FIG. 1.0 - Model 611612001 AZ/EL w/Fine Tune
Option
CLAMP BRACKET
HEX NUT,
CARRIAGE BOLT (4)
HALF CLAMP (2)
CLAMP BOLTS
(CARRIAGE BOLT &
HEX NUT (4)
FIG. 1.1 - Model 611612002 AZ/EL w/o Fine
Tune Option
MOUNT ASSEMBLY
LOCK WASHER
(4 REQ)
HEX NUT
(2 REQ)
PLOW BOLT
M8 x 1.25 x 56
(.96m ONLY)
SIDE BOLT
HOLE
CLAMP
BOLTS
(2 REQ) .96m
PLOW BOLT
BOTTOM
GROUND
M8 x 1.25 x 91
BOLT
POLE
(QTY. 4, 1.2m)
HOLE
FIG. 1.2 - Assembling Reflector to AZ/EL Mount
and Ground Pole (.96cm Shown)
5
ELEVATION DEGREES
MECHANICAL
(4 REQ)
10
20
30
40
50
60
70
M o Based on 41.5" (1054 mm) from Mounting Surface of Center Line of Antenna
Values shown represent maximum forces for any wind direction and
include 1.5 F s . Height and exposure factors from uniform building code
are NOT included.
APPENDIX A
96cm Antenna Survival Windloads at 125 MPH Velocity
o
15.4
OFFSET
F H
(NORMAL TO ANTENNA FACE)
41.5" HEIGHT
(1054 mm )
M T
F V
M O
FORCE (POUNDS)
BEAM
F
F
H
V
0
15
747
-20
25
707
-150
35
687
-289
45
622
-413
55
548
-498
65
478
-548
75
398
-573
85
299
-443
12
F
= Horizontal Force
H
F
= Vertical Force
V
M
= Torsional Moment
T
M
= Overturning Moment
O
MOMENTS (FT-LBS/N-m)
M
M
T
O
150
2584
147
2445
139
2376
126
2151
107
1896
90
1653
70
1377
54
1034