1
Dismantling the
Remove the brush holders (1) from the
motor
machine. Remove the screw of the
retaining clip (8). Remove the retaining
clip and the carbon brushes.
2
Remove the gear case from the motor
housing.
3
Remove the complete motor from the
armature (4). Remove the gear.
4
Expel the armature (4) from the gear case
with aid of a plastic hammer.
5
Remove the screws and the cover (6) with
the gasket. Lever off the piston together
with the connecting rod (5).
6
Unscrew the eccentric wheel shaft (7) and
hit it until it comes free. If necessary, use
a plastic hammer.
7
Separate the eccentric, the bearing, the
ball bearing, the locking ring, and the
pinion from the eccentric wheel shaft (7)
by pressing.
8
Lever off the air conduction ring (2).
9
Lightly hit the electric field (3) to remove it.
1
Dismantling the
Unscrew and dismantle the pair of handle
On/Off switch
shells (1).
2
Unscrew and dismantle the switch (3), the
capacitor (2), and other electric parts.
Repair Instructions No. 162.11/95
PHD 26/ PH(D) 38/ PH 240 D/ PH 350 (D)
6
5
4
3
2
1
3
2
1
PAGE
3
7
5
1
8
6