Alert-it Care Systems P161B Kullanıcı/ Kurulumcu El Kitabı - Sayfa 2

Güvenlik Sistemi Alert-it Care Systems P161B için çevrimiçi göz atın veya pdf Kullanıcı/ Kurulumcu El Kitabı indirin. Alert-it Care Systems P161B 13 sayfaları. Radio door activity monitor

This handbook is intended to assist carers install, configure and use the monitors.
The carere therefore needs to understand the needs of the user and asses that the
monitor meets those needs and if any supplementary monitoring is needed taking
into account any health risks.
The P161 is a highly configurable door switch that can be used to warn of a door
being opened. It can be used as a latched alarm on Emergency Doors and External
Doors or as a transient warning of the use of internal doors as may be required in
the care of those with dementia. Staff can reset any alarm while the door is open,
and the alarm will not sound again until the door first closes. This allows the door
to be left open, under supervision. There are no vulnerable switches but simple
keys are available which are left inserted as a visible sign the unit is disabled,

Pager Operation

The alarm is passed by the Alert-iT high integrity radio link to the carers pager. The
link can operate in Securelink mode which constantly checks the link is working
and raises the alarm if it fails

Power connection

For stand alone systems the P162B features a radio link to the P137/P138 pagers.
UH1115 P161B Door Activity Handbook.ppp page 2 of 12
First time activation:
On arrival, and after
battery replacement, press
the front PRESS area until
a beep is heard to activate
the unit