D-304681
PG9901/PG8901/PG4901
Supervised Wireless PowerG Indoor Siren
Installation Instructions
Overview
The PGx901 is a fully supervised, 2 way wireless PowerG indoor
siren. Designed for installation in areas where wiring is difficult or
impossible.
Features
• Built-in link quality indicators reduce installation time by
eliminating the need for the installer to physically approach
the control panel.
• Multiple sound types: Burglar (between 1400Hz - 3200Hz),
fire, gas/CO and flood.
• Entry/Exit beep can be enabled via the control panel to sound
once the user has armed the system and once the user has
entered the protected area.
• Squawk (beep) sounds can be configured via the control panel
to indicate alarm system arming (1 squawk) and disarming (2
squawks) by a wireless key.
• Double Tamper protection sends a tamper alarm to the system
if the siren front panel is removed or if the siren is removed
from the wall.
Notes: Sounder is activated for a predefined duration according to
local requirements, or until the system is disarmed. The strobe light
operates as described in the HSM2HOST installation manual.
Operation
• Siren and strobe light activate when an identified event
message is received from the alarm system.
• When the battery voltage is low, a low battery message is sent
to the alarm system. After message delivery, at least 2 siren
alarms are possible before the siren is totally inactive.
Device Setup
Caution! To be installed by service persons in non-hazardous loca-
tions only. Risk of explosion if battery is replaced by an incorrect
type. Observe polarity when installing batteries. Dispose of used bat-
teries according to the manufacturer's instructions and according to
local rules and regulations.
WARNING: Batteries are to be replaced by service persons only.
Note: To ensure the continued operation of all wireless devices after
performing a system default, a global upload of all wireless pro-
gramming via DLS is recommended before defaulting the system.
After completing the system default, download the wireless pro-
gramming.
Legend
A. Battery
B. Battery cable
C. Battery connector
D. Enroll button
E. Self test button
F.
For back tamper screw
Installing Battery
1
1. Loosen cover screw and
remove cover.
2. Insert battery pack and
securely insert the
battery cable (B) into
the battery connector
(C).
2
B
Note: When manually pro-
gramming wireless devices,
A
if a device has been pow-
ered up for more than 48
hours it cannot be enrolled
into the system until the
B
device has been tampered
and restored. When pro-
C
gramming the panel using
the Quick Enroll procedure
A
D
follow the steps detailed in
E
"Enroll the Device" below
Note: After restoring a low battery trouble the system may take
up to 5 minutes to clear the trouble.
Enroll the Device
To quick enroll:
1. On a keypad press [*] [8] [Installer Code] [804] [000].
2. Press and hold the device enroll button until the LED lights
steady and then release the enroll button while the LED is still
lit. A confirmation message then appears on the keypad.
3. Press [*] key to confirm ID.
4. Enter [3 digit siren #].
5. Enter [1 digit partition #] for all desired partitions and press [#].
If using an LCD keypad you can scroll to the desired partitions
and press [*] to toggle the partition.
6. On an LCD keypad enter the label by using word library.
To pre-enroll:
1. Remotely configure the unique ID number into the system. For
more information see the HSM2HOST manual.
2. When on-site, press the device enroll button.
Note: If the wireless device has been powered for more then 48 hours
without being enrolled, tamper and restore the device to enroll it.
Local Diagnostics and Placement Test
Before permanently mounting any wireless device it is recom-
mended to mount the device temporarily and perform a Local Diag-
nostics test.
1. Before testing, remove the plastic cover.
2. Press the self-test button once and release it; The red LED will
switch ON and then OFF, the green LED will switch ON and
then OFF, the strobe light will switch ON and then OFF and the
piezo siren will sound to indicating that the siren is fully
operational.
3. After 2 seconds the LED blinks 3 times indicating the signal
strength.
The following table indicates the received signal strength.
LED response
Reception
Green LED blinks
STRONG
Orange LED blinks
GOOD
Red LED blinks
POOR
No blinks
No communication
IMPORTANT! Only GOOD or STRONG signal strengths are
acceptable. If you receive a POOR signal from the device, re-locate
it and re-test until a GOOD or STRONG signal is received.
Note: For UL/ULC installations, only STRONG signal levels are
acceptable. After installation verify the product functionality in con-
junction with the compatible receivers HSM2HOST9, HS2LC-
DRF(P)9, HS2ICNRF(P)9 and PG9920.
Note: For detailed Placement instructions refer to the control panel
Reference Guide.
Mounting the Device
(*)
2
1
F
3
1. Mark for drilling.
2. Drill 4 holes.
3. Fasten with 4 supplied screws.
Configuration
To enter the wireless configuration section enter [804][551-566].
Partition Assignment
[000]
Press the digits of desired assigned partitions.
[001]
Device Toggles
The following are 8-bit toggles
01- Fire - Default [Y]
02- CO - Default [Y]
03- Burg - Default [Y]
04- Flood - Default [Y]
06- Auto Tmp Alarm - Default [N]
[002]
Strobe Alarm - Default [01]
01 - Disabled
02 - Timer Limited
03 - Until Disarmed
Exit Entry Beeps - Default [01]
[003]
01 - Disabled
02 - Enabled
03 - Disabled Stay
[004]
Squawk - Default [02]
01 - Disabled
02 - Sounder Only
03 - Strobe Only
04 - Sounder and Strobe
[001][06]
Sounder Volume - Default [02]
01 - Low
02 - Medium
03 - High

Specifications

Alarm Sound Level: 85 dB at 3 m (10 feet)
Frequency Band (MHz): CE Listed PG4901: 433MHz; CE/EN
listed PG8901: 868MHz; FCC/IC/UL/ULC listed PG9901: 915MHz
Modulation: GFSK
Antenna: Built-in antenna
Communication Protocol: PowerG
Siren Type: One Piezo 109 db min. Sound Pressure Level @ 1m,
1400Hz – 3200 Hz, sweep frequency 7 Hz.
Battery Type: 3.6V/14.5A/H Lithium battery (EVE ER34615M/
w200) (not verified by UL/ULC)
Note: Use only the above battery.
Note: The strobe flashes 5 times and the red LED lights continu-
ously during first battery installation.
Battery Life Expectancy: 8 years (not verified by UL/ULC)
Low Battery Threshold: 2 V +300 mV negative slope OR 1.2 V
Strobe Light: Pulsed @ 1 sec.
Temperature range: -10ºC to +55ºC (UL/ULC only verified the
range 0º-49ºC)
Relative Humidity: up to max. 93%RH, non-condensing (UL/ULC
only verified up to max 85%RH)
Dimensions (LxWxD): 161x161x50mm (6-7/16 x 6-7/16 x 1-3/4
in)
Weight (including battery): 470g (16.5 oz.)
Color: White (with transparent lens)

Compatible Receivers

433MHz Band: HSM2HOST4; HS2LCDRF(P)4; HS2ICNRF(P)4;
PG4920
868MHz Band: HSM2HOST8; HS2LCDRF(P)8; HS2IC-
NRF(P)8;PG8920
912-919MHz Band: HSM2HOST9; HS2LCDRF(P)9; HS2IC-
NRF(P)9; PG9920
Note: Only devices operating at 912-919MHz are UL/ULC listed.
Note: Only model PG9901 operating in the frequency band 912-
919MHz is UL/ULC listed.
UL/ULC Notes
The PG9901 has been listed by UL/ ULC for Residential Burglary /
Fire applications in accordance to UL 1023/ C1023 Household bur-
glar Alarms system units and UL 985/ULC-S545 Household fire.
Europe: The PG4901 and PG8901 are compliant
with the RTTE requirements - Directive 1999/5/EC
of the European Parliament and of the Council of 9
March 1999. The PG8901 is certified by DNV (DET
NORSKE VERITAS) to the following standards: EN50131-4,
EN50131-1 GRADE 2, CLASS II, EN50131-6 Type C. DNV
(DET NORSKE VERITAS) has certified only the 868 MHz
variant of this product. According to EN 50131-1:2006 and
A1:2009, this equipment can be applied in installed systems up
to and including Security Grade 2, Environmental Class II. UK:
The PG8901 is suitable for use in systems installed to conform
to PD6662:2010 at Grade 2 and environmental class 2. BS8243
The Power G peripheral devices have two- way communication
functionality, providing additional benefits as described in the
technical brochure. This functionality has not been tested to
comply with the respective technical requirements and should
therefore be considered outside the scope of the product's certi-
fication.
FCC COMPLIANCE STATEMENT
WARNING! Changes or modifications to this unit not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in residential installations. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio and television reception.
However, there is no guarantee that interference will not occur in a particular installation. If this device
does cause such interference, which can be verified by turning the device off and on, the user is encouraged
to eliminate the interference by one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from the one that supplies power to the receiver.
– Consult the dealer or an experienced radio/TV technician.
This equipment complies with FCC and IC RF radiation exposure limits set forth for an uncontrolled
environment.
WARNING! To comply with FCC and IC RF exposure compliance requirements, the smoke detector
should be located at a distance of at least 20 cm from all persons during normal operation. The antennas
used for this product must not be co-located or operated in conjunction with any other antenna or
transmitter.This device complies with FCC Rules Part 15 and with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference that may be received or that may cause
undesired operation.
IC:160A - PG9901
The term "IC" before the radio certification number only signifies that Industry Canada technical
specifications were met.
Le present appareil est conforme aux CNR d'Industrie Canada appli-
cables aux appareils radio exempts de licence. L'exploitation est
autorisee aux deux conditions suivantes :(1) l'appareil ne doit pas
produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter
tout brouillage radioelectrique subi, meme si le brouillage est sus-
ceptible d'en compromettre le fonctionnement.
PG9901/PG8901/PG4901
Instructions d'installation de la sirène
d'intérieur sans fil surveillée de la gamme
PowerG
Vue d'ensemble
Le PGx901 est une sirène d'intérieur entièrement surveillée,
bidirectionnelle, sans fil, de la gamme PowerG. Destiné à une
installation dans les zones où le câblage est difficile, voire
impossible.
Caractéristiques
• Les indicateurs de qualité de liaison intégrés réduisent les
temps d'installation en supprimant la nécessité de l'installateur
d'être physiquement à proximité de la centrale.
• Différents types de son : Intrusion (entre 1400 Hz et 3200 Hz),
incendie, gaz/CO et inondation.
• Le bip sonore d'entrée/sortie peut être activé par
l'intermédiaire de la centrale pour sonner une fois que
l'utilisateur a armé le système et une fois qu'il est entré dans la
zone protégée.
• Les tonalités (bips sonores) peuvent être configurées par
l'intermédiaire de la centrale pour indiquer l'armement (1
tonalité) et le désarmement (2 tonalités) du système d'alarme à
l'aide d'une télécommande.
• La double protection anti-sabotage transmet une alarme de
sabotage au système si le panneau avant de la sirène est retiré
ou si la sirène est décrochée du mur.
Remarques : L'avertisseur est activé pour une durée prédéfinie
selon les exigences locales ou jusqu'à ce que le système soit
désarmé. La lampe stroboscopique fonctionne comme décrit dans le
manuel d'installation HSM2HOST.
Fonctionnement
• La sirène et la lampe stroboscopique se déclenchent quand un
message d'événement identifié est reçu depuis le système
d'alarme.
• Quand la tension de batterie est faible, un message de niveau
batterie de pile est transmis au système d'alarme. Après la
transmission du message, au moins 2 alarmes de la sirène sont
possibles avant que la sirène ne devienne complètement
inactive.
Réglage du dispositif
Attention ! À faire installer par un agent de service dans des zones
non dangereuses uniquement. Risque d'explosion si la pile n'est pas
du type correct. Respecter les polarités lors de l'installation des piles.
Éliminer les piles usagées selon les recommandations du fabricant,
les lois et réglementations locales.
AVERTISSEMENT!
Les
piles
doivent
être
remplacées
uniquement par un agent de service.
Remarque : Pour garantir le fonctionnement continu de tous les
dispositifs sans fil après avoir réalisé une réinitialisation aux valeurs
par défaut, un téléchargement général de toute la programmation
sans fil par DLS est recommandé avant de réinitialiser le système.
Après avoir complété la réinitialisation aux valeurs par défaut du
système, téléchargez la programmation sans fil.
Légende
1
A. Batterie
B. Câble de pile
C. Connecteur de la
batterie
D. Bouton
d'attribution
E. Bouton
d'autodiagnostic
2
B
F.
Vis du contact
arrière anti-
A
sabotage
Installation de
la batterie
B
1. Desserrez la vis du
couvercle et retirez le
C
couvercle.
2. Insérez le bloc-piles
A
D
et insérez
E
soigneusement le
câble de pile (B) dans
le connecteur de
pile (C).
Remarque : Quand vous programmez manuellement les dispositifs
sans fil, si un dispositif a été alimenté pendant plus de 48 heures, il
ne peut pas être attribué dans le système tant que le dispositif n'a pas
été saboté et rétabli.
Remarque: Après la restauration d'un défaut de batterie faible,
le système peut prendre jusqu'à 5 minutes pour que la peine.
Attribuez le dispositif dans le système
Pour une attribution rapide :
1. Sur le pavé numérique, appuyez sur [*] [8] [Code de
l'installateur] [804] [000].
2. Appuyez de façon prolongée sur le bouton d'attribution du
dispositif tant que le voyant lumineux reste allumé, puis
relâchez- le bouton d'attribution alors que le voyant lumineux
est encore allumé. Un message de confirmation apparaît alors
sur le pavé numérique.
3. Appuyez sur la touche [*] pour confirmer le ID.
4. Entrez le [3 sirène chiffres #].
5. Entrez le [n° de partition à 1 chiffre] pour toutes les partitions
souhaitées et appuyez sur [#]. Si vous utilisez un pavé
numérique à cristaux liquides LCD, vous pouvez faire défiler
les partitions souhaitées et appuyer sur [*] pour basculer la
partition.
6. Sur un pavé numérique LCD, entrez la référence en utilisant la
bibliothèque de mot.
Pour une attribution préalable :
1. Configurez à distance le numéro ID unique dans le système. Pour
plus d'informations, consultez le manuel HSM2HOST.
2. Sur site, appuyez sur le bouton d'attribution du dispositif.
Remarque : Si le dispositif sans fil a été alimenté pendant plus de
48 heures sans être attribué, sabotez et rétablissez le dispositif pour
l'attribuer.
Diagnostics locaux et test de positionnement
Avant de fixer de façon permanente un dispositif sans fil
quelconque, il est conseillé de le monter temporairement et
d'effectuer un test de diagnostic local.
1. Avant de tester, retirez le cache en plastique.
2. Appuyez une fois sur le bouton d'autodiagnostic et relâchez. Le
voyant lumineux rouge s'allume puis s'éteint, le voyant
lumineux vert s'allume puis s'éteint, la lampe stroboscopique
s'allume puis s'éteint et la sirène piézoélectrique retentit pour
signaler qu'elle est entièrement opérationnelle.
3. Au bout de 2 secondes, le voyant clignote 3 fois pour indiquer
la force du signal.
Le tableau suivant décrit la force de signal reçu.
Réponse du voyant
Réception
Le voyant vert clignote
FORT