Abus AZSG10005 Kurulum Talimatları ve Kullanım Kılavuzu - Sayfa 17

Güvenlik Sistemi Abus AZSG10005 için çevrimiçi göz atın veya pdf Kurulum Talimatları ve Kullanım Kılavuzu indirin. Abus AZSG10005 19 sayfaları. Wired outdoor siren

Abus AZSG10005 Kurulum Talimatları ve Kullanım Kılavuzu

Maintenance

[LK6] Intermittent
If selected, the siren sounds for a maximum of three passes.
50 sec. ON, 40 sec. OFF, 50 sec. ON, 40 sec. OFF, 50 sec. ON and then stops. (Times
approximate)
[LK7] 15 min.
If selected, the siren sounds for a maximum of 15 minutes.
[LK8] 3 min. (default setting)
If selected, the siren sounds for a maximum of 3 minutes.
[LK9] Sound Output
Allows the choice between 100 dB (A) @ 1 m (default setting) and 85 dB (A) @ 3 m.
Operation of the comfort LEDs
In normal operation, the comfort LEDs are not illuminated when the sounder is connected to the
power supply, to visually display that the system is operational.
If the tamper contact is opened and/or the power supply is interrupted, this is indicated by the
respective LED (No 13 + 14 Fig. 2) flashing.
Maintenance
Be prepared, that the alarm will be activated as soon as you open the sounder's
cover. Make sure that any loud sounds emitted, do not startle you, causing you
Caution
to fall off the ladder.
 Test, during routine maintenance, that the sounder works properly.
 Check the tamper contact, check for signs of seeping water or insects and clean the device
as required.
 Put the terminal cover back on, close the lid, tighten the cover fixing screws and close the
screw's covers.
 Test the system.
17