Audiovox Keyless Entry Alarm Upgrade Module APS-30 Kurulum Talimatları Kılavuzu
TYPICAL 2-STEP DIAGRAM
DRIVER'S
D/L MOTOR
"DISARM INPUT #1"
RIGHT FRONT
D/L MOTOR
"DISARM INPUT #2"
RIGHT REAR
D/L MOTOR
LEFT REAR
D/L MOTOR
DOOR LOCK
CONNECT
"ARM" INPUT
HERE
UNLOCK
LOCK
WIRING THE ARM / DISARM INPUTS IN VEHICLES WITHOUT 2 STEP UNLOCK
GREEN WIRE : ( + or - ) ARM INPUT
Connect this wire to the driver's door lock motor wire, which will receive +12 volts when the doors are locked
using the door panel switch or the remote transmitter.
RED WIRE : DISARM INPUT # 1
Connect this wire to the unlock output wire from the OEM keyless entry control module. Refer to the
diagram..
RED w/ BLACK TRACE WIRE : DISARM INPUT # 2
If the Red wire is switched to +12 volts when the doors are unlocked, connect the Red w/Black Trace wire
to ground.
If the Red wire is switched to ground when the doors are unlocked, connect the Red w/Black Trace wire
to +12 volts.
BLUE WIRE : (+) TRUNK TRIGGER SHUNT INPUT
This wire will determine if the vehicle's trunk has been opened using the OEM transmitter, and stop the alarm from triggering when
the transmitter is used.
Connect this wire to the + 12 volt trunk release output from the OEM Keyless Entry module.
VALET SWITCH : Plug the 2 pin connector from the valet switch into the mating 2 pin connector on the control module.
L.E.D. : Plug the 2 pin connector from the L.E.D. into the mating 2 pin connector on the control module.
Printed in Taiwan
128-4515
FACTORY
REMOTEKEYLESS
ENTRY MODULE
DRIVER'S
CONNECT
DOOR UNLOCK
RELAY
HERE.
A L L
A LL
CONNECT
UNLOCK
LOCK
OUTPUT
OUTPUT
HERE.
FACTORY
RELAYS
DOOR PANEL
LOCK / UNLOCK
SWITCH
+
UNLOCK
+
LOCK
Audiovox Corp., 150 Marcus Blvd. Hauppauge, N.Y. 11788
TYPICAL ONE-STEP DIAGRAM
DRIVER'S
D/L MOTOR
+
RIGHT FRONT
D/L MOTOR
RIGHT REAR
D/L MOTOR
LEFT REAR
D/L MOTOR
CONNECT
"ARM" INPUT
HERE
CONNECT
"DISARM INPUT #2"
TO CHASSIS GROUND
REMOTEKEYLESS
ENTRY MODULE
UNLOCK
OUTPUT
CONNECT "DISARM
INPUT #1" HERE
THEN CUT THE WIRE
AND ADD A DIODE,
AS SHOWN.
IF GROUND SWITCHED
DOOR LOCKS - TURN
DIODE TO FACE INTO THE
KEYLESS MODULE AND
CONNECT DISARM #2 TO
+12 VOLTS
FACTORY
DOOR LOCK RELAYS
+
UNLOCK
LOCK
+
FACTORY
A LL
AL L
LOCK
OUTPUT
DOOR PANEL
LOCK / UNLOCK
SWITCH
UNLOCK
LOCK
Form No.