Abus PLBW10100 Manuel - Sayfa 16

Güvenlik Sensörleri Abus PLBW10100 için çevrimiçi göz atın veya pdf Manuel indirin. Abus PLBW10100 18 sayfaları. Nexello motion detector
Ayrıca Abus PLBW10100 için: Hızlı Kılavuz (2 sayfalar)

Abus PLBW10100 Manuel

3.4. Configuration parameters

Z-Wave products can be used directly after inclusion in the network. However, configuration settings
can be used to adapt the behaviour of the device even better to the requirements of the application and
to activate additional functions.
Use your Z-Wave controller to initiate the changes to the parameters. In order for the device to receive
the values, a wake-up must be performed on the device itself. (see point 2.5)
Para-
Byte
meter
size
10
1
12
1
Waiting time between
13
2
two motion alarms
14
1
association group 2
Invert value of BASIC
15
1
16
1
17
1
Function
Threshold value
battery alarm
PIR sensor
Active / Deactive
BASIC SET to
(motion alarm)
SET command
Sensitivity
PIR sensor
Pet Immunity
Active / Deactive
Default
Description
value
Percentage value from when the low battery
alarm should be transmitted.
10
Adjustable from 5 - 50 in percent
(Hexadecimal: 0x05 - 0x32)
Enable / disable the PIR sensor.
0 = Sensor is deactivated
1
1 = Sensor is activated
(Hexadecimal: 0x00 - 0x01)
Waiting time from one motion alarm to the next
triggering.
60
Adjustable from 5 - 15300 in seconds
(Hexadecimal: 0x05 - 0x3BC4)
BASIC SET should be sent after a motion
alarm.
0
0 = Disabled
1 = Active
(Hexadecimal: 0x00 - 0x01)
Set the value of the BASIC SET command for
movement alarm and acknowledgement.
0 = The motion alarm sends the BASIC
SET value "On" (0xFF), the
acknowledgement sends the BASIC SET
value "Off" (0x00)
0
1 = The motion alarm sends the BASIC
SET value "Off" (0x00), the
acknowledgement sends the BASIC SET
value "On" (0xFF)
(Hexadecimal: 0x00 - 0x01)
Sensitivity value of the PIR sensor.
The value 10 is the highest sensitivity.
9
The value 1 is the lowest sensitivity.
Adjustable from 1 - 10
(Hexadecimal: 0x01 - 0x0A)
Activate/deactivate the pet immunity.
0 = Pet immunity is deactivated
0
1 = Pet immunity is activated
(Hexadecimal: 0x00 - 0x01)
16
English