Abus SHRM10000 Orijinal Kullanım Talimatları - Sayfa 15
Duman Alarmı Abus SHRM10000 için çevrimiçi göz atın veya pdf Orijinal Kullanım Talimatları indirin. Abus SHRM10000 16 sayfaları. Z-wave smoke detector
Group
Maximum
Number
Devices
Group 1
0x05
Group 2
0x05
Group 3
0x05
6.2.
Supported Command Classes
1
Z-Wave plus Info Version 2
2
Notification Version 8
3
Association Version 2
4
Association Group Info Version 1
5
Transport Service Version 2
6
Version Version 3
7
Manufacturer Specific Version 2
8
Device Reset Locally Version 1
9
Powerlevel Version 1
10
Battery Version 1
11
Security 2 Version 1
12
Supervision Version 1
13
Wake Up Version 2
7. Technical Specifications
Parameters
Dimensions
Weight
Operating Temperature
Max. Humidity
IP Class
Radio frequency
Material
Transmission power
Power supply
Battery type
Transmitted Content
Association group 1: Lifeline association group Include
command classes: Battery report, Notification report, and
Device Reset Locally notification, Binary report.
Association group 2: Root Device group(Binary Sensor)
Binary Sensor Command Class: Compatible with 300
series 1-Binary Sensor reports status of smoke or no
smoke via Lifeline. 2-When the sensor detects
status change between smoke and no smoke, the device
will be triggered.
Association group 3: Root Device group(Notification) 1-
Notification reports reports status of detect smoke or no
smoke via Lifeline. 2-When the sensor detects status
change between smoke and no smoke, the device will be
triggered.
Unit
mm
g
°C
%
MHz
db
15
SHRM10000
60 x 60 x 49,2
66
0 – 40
95
20
868,42 (Z-Wave PLUS, Europe)
ABS, poliert
< 4,5
3 V DC
CR123 (CR17335) EVE (1500mA)
English